What is the maximum amperage of the engine-driven generators?
400 amps. AOM 2-05-05 page 1.
What is the maximum amperage of the APU generator?
400 amps up to and including 30,000 ft, 300 amps above 30,000 ft.
AOM 1-01-32 page 1.
What are the battery specifications?
24 VDC, 44 Ah NiCad (2). AOM 2-05-05 page 6.
Can the GPU charge the batteries?
No. AOM 2-05-05 page 6
What is the minimum battery temperature for APU start?
-20°C. AOM 1-01-38 page 1.
Which bus supplies power to the inverter?
DC Bus 1. AOM 2-05-05 page 12
What are the consumers of inverter power?
TCAS II, EGPWS/Windshear. AOM 2-05-05 pa
What light illuminates in the overhead panel GPU button when the GPU is connected and on?
GPU AVAIL. AOM 2-05-05 page 5
What should the GPU voltage indicate on the MFD when it is connected and available?
26 VDC to 29 VDC.
AOM 1-12-05 page 1.
Do the generators or the GPU have priority?
GPU.
AOM 2-05-05 page 5.
Which bus is supplied with power when the GPU is selected and the batteries are OFF?
Ground service bus.
AOM 2-05-05 page 10.
What items are powered from the Ground Service Bus?
AOM 2-05-05 page 10.
- Passenger cabin lights
- Lavatory lights
- Galley lights
- Courtesy/stair lights
- Cockpit dome lights
- Baggage/service compartment lights.
What is considered an electrical emergency?
Loss of all generators.
AOM 2-05-10 page 25.
The batteries can supply essential power for how many minutes in the event of an electrical emergency?
40 minutes, which includes 3 APU start attempts.
AOM 2-05-05 page 6
What does the Essential Power Button do?
Overrides auto transfer (EDL logic) to electrical emergency configuration and ensure batteries power only the Essential Buses. Isolates batteries from DC buses.
AOM 2-05-15 page 3.