EICAS System Flashcards

1
Q

After the failure of ED1, how can the status page be displayed?

A

Either Select the MFD Reversionary Panel to EICAS or select the EICAS selector on the source selector panel to ED2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

If one of the DCU disable switchlights is pressed, all voice messages will be inhibited except for _____and _______ warnings.

A

EGPWS/TCAS.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

In the event of power failure of the EICAS Control Panel (ECP), what buttons will still be operational?

A

PRI/STAT/CAS/STEP.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When can caution messages can be paged and boxed?

A

Paged on the ground with the engines shut down, boxed with both engines at stabilized idle and boxing in flight is a function of WOW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What EICAS messages cannot be paged

A

Warnings (red) and advisories (green).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What EICAS messages cannot be removed from view by boxing?

A

Warnings (red) and advisories (green).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

If a red warning message is generated on ED1 what other indications will/may accompany it?

A

Flashing Master Warning light, triple beep, and possible aural warning depending on the cause of the alert.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly