Eng oil ECAM ADV
Below 2 quarts
APU low oil ECAM ADV
If no leak, 15 hrs of operation
CAB PR ECAM ADV
Cab v/s > 1800’/m, cab alt > 8000’, dif pr >1.5psi on grd
CPC change over (man 3 sec, auto), Ldg elev change
Elec IDG oil ECAM ADV
IDG oil temp > 150 degrees C, reduce load, galley or gen off
Eng oil ECAM ADV
Eng oil > 160 > 175 degrees C for 15 min, gen load reduce, IDG disconnect
Eng oil ECAM ADV qty
Below 2 quarts, (if continues to decrease and oil lo pressure checklist?, shutdown?)
Eng Nac temp ECAM ADV
Above 260 degrees C, monitor
Eng Vib ECAM ADV
N1 equal or above 5.7 (QRH CL= reduce thrust, if possible til below adv)
N2 equal or above 5.6 (as above)
Fuel ECAM ADV
L & R differ by 3000kg, fuel management check, fuel leak C.L.
Oxy/Door CKPT oxy ECAM ADV
Pulses green below 600 psi
Pulses amber below 300 psi