E190 FIRE PROTECTION Flashcards

1
Q

What happens when you pull fire EXT red handle?

A
Closes: 
Bleed valve
Fuel SOV
Hydraulic SOV
Generator line contactor will open as eng decelerates
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Inflight, with NO smoke indication in the FWD COMPARTMENT, how many pushes of the sw is required to activate BOTH bottles?

A

2
1st arms the high rate (light comes on)
2nd discharges HIGH rate and 60 sec later LOW will automatically discharge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Smoke detected inflight (FWD COMPARTMENT) What happens when you press the FWD cargo smoke button?

A

Discharged HIGH rate bottle

LOW rate discharges automatically 60 sec later

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

While touring the cockpit a curious customer presses the AFT SMOKE button and it turns red. What has happened?

A

HIGH rate bottle is armed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How do you “unarm” an erroneously pressed CARGO SMOKE button?

A

Press the TEST button or wait 2 mins

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

On the ground, smoke detected FWD CARGO, what happens when you press the red button?

A

1st push: discharges HIGH rate bottle

2nd push: LOW rate bottle

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What should you check before testing the fire detection system?

A
Confirm there are no FIRE related EICAS messages
FIRE DET FAIL
FIREX FAIL
FIREX ARM
BTL DISCH
How well did you know this?
1
Not at all
2
3
4
5
Perfectly