E190 FIRE PROTECTION Flashcards
What happens when you pull fire EXT red handle?
Closes: Bleed valve Fuel SOV Hydraulic SOV Generator line contactor will open as eng decelerates
Inflight, with NO smoke indication in the FWD COMPARTMENT, how many pushes of the sw is required to activate BOTH bottles?
2
1st arms the high rate (light comes on)
2nd discharges HIGH rate and 60 sec later LOW will automatically discharge
Smoke detected inflight (FWD COMPARTMENT) What happens when you press the FWD cargo smoke button?
Discharged HIGH rate bottle
LOW rate discharges automatically 60 sec later
While touring the cockpit a curious customer presses the AFT SMOKE button and it turns red. What has happened?
HIGH rate bottle is armed
How do you “unarm” an erroneously pressed CARGO SMOKE button?
Press the TEST button or wait 2 mins
On the ground, smoke detected FWD CARGO, what happens when you press the red button?
1st push: discharges HIGH rate bottle
2nd push: LOW rate bottle
What should you check before testing the fire detection system?
Confirm there are no FIRE related EICAS messages FIRE DET FAIL FIREX FAIL FIREX ARM BTL DISCH