1/_
How much of the bowl do you INITIALLY FILL WITH WATER?
1/3 with water
_ inch(s)
How much do you rod (penetrate) the top of the mix at a time?
1 inch
8-_
How many times do you tap the sides AFTER RODDING?
8-12 times AFTER RODDING
You __ after you finish EACH the filling, rodding, and mallet procedure of the measure to REMOVE ANY TRAPPED AIR BUBBLES.
Stir
First step after clamping on pressure meter lid?
Add water through petcocks to flush out air.
What is the next step AFTER ADDING WATER TO PETCOCKS?
Attach a spray tube to one petcock.
Do you close the other petcock AFTER ADDING THE SPRAY TUBE TO ONE PETCOCK?
(YES OR NO)
YES
What is the next step after adding the flow tube to one petcock AND closing the other petcock?
Pump the meter up to the IP line.
What do you do after pumping of the meter to the IP line?
Release the main release valve
Will collect water from inside the pressure meter.
What do you do after draining the initial water from the measure?
Repump meter to the IP line.
What do you do after you REPUMP the meter to the IP line?
Release pressure via main valve and hit meter with hammer smartly
When do you know the direct ready of the ACF
After you WHAT?
Release air from main valve and hit measure with hammer smartly
Same ass mallet consolidation.
How many times do you ROD each lift of the measure?
8-12 times