DC Electrics Flashcards
1
Q
A battery discharge condition is indicated by the battery load indicator showing:
- Less than 24 volts
- A flashing negative indication
- A flashing positive indication
- Less than 28 volts
A
- A flashing negative indication
2
Q
The buses in the DC system which can be manually tied by the crew are:
- The essential buses
- The main feeder buses
- None
- The secondary distribution buses
A
- The main feeder buses
3
Q
The function of the TRUs is to:
- Convert variable frequency AC to DC
- Convert variable frequency AC to fixed frequency AC
- Provide rectified DC power in the event of a DC generator failure
- Convert DC to variable frequency AC
A
- Convert variable frequency AC to DC
4
Q
The left TRU supplies the:
- Left secondary bus with 115v fixed frequency AC
- Left secondary bus with 25-29.5 volts DC
- Left secondary bus with 115v variable frequency AC
- Left secondary bus with 26v AC via step down transformers
A
- Left secondary bus with 25-29.5 volts DC
5
Q
The bus bar protection unit:
- Deselects the AC generators if overloaded, after a 7 second delay
- Protects the batteries from overheating
- Monitors the generators for over voltage conditions
- Protects the batteries and generators from overloads by isolating them
A
- Protects the batteries and generators from overloads by isolating them
6
Q
When external DC is selected, the aircraft’s electrical system is protected from a faulty external power unit by:
- The BBPU
- An over voltage relay
- The GCU’s
- The BBPU and GCU’s
A
- An over voltage relay
7
Q
When the BATTERY MASTER switch is selected on:
- The batteries are ready to accept a charge from the Main Feeder buses
- the auxiliary and main batteries energise the secondary buses
- the batteries are connected to the essential buses
- The batteries are connected to the main DC buses
A
- the batteries are connected to the essential buses
8
Q
When a battery temperature monitor indicates an over temperature condition:
- Air conditioned cool air is directed over the battery
- An audio warning is activated and the QRH should be consulted
- The battery must be manually isolated from the generating system
- A BATT HOT caution light illuminate, and the battery is automatically isolated
A
- The battery must be manually isolated from the generating system