1
Q
Loss of the left main DC bus results in:
- Loss of auxiliary inverter
- Loss of primary inverter with no effect on left or right 400hz buses
- Loss of auxiliary and primary inverter
- Loss of primary inverter and left 400hz bus
A
- Loss of auxiliary inverter
2
Q
The AUXILIARY inverter switch on the AC CONTROL panel allows:
- The 400hz bus-tie contractor to be opened or closed
- All inverters to be selected off in an emergency
- The auxiliary inverter to power the 115v variable frequency buses
- The auxiliary inverter output to be selected manually, to the left or right 115 volt 400hz bus
A
- The auxiliary inverter output to be selected manually, to the left or right 115 volt 400hz bus
3
Q
The AC and DC generators are driven by:
- A RAM air turbine
- High-pressure bleed air
- The propeller reduction gearbox and the accessory gearbox, respectively
- The accessory gearbox and the prop reduction gearbox, respectively
A
- The propeller reduction gearbox and the accessory gearbox, respectively
4
Q
The GCU on the AC generator maintains a constant:
- Voltage of 115 AC
- Voltage of 28 DC
- Frequency and voltage
- Frequency of 400 hz
A
- Voltage of 115 AC
5
Q
If the No.1 AC generator fails, the left AC bus is powered by the:
- Right TRU
- Left TRU
- No. 2 AC generator
- Bus is not powered
A