Damage Control Fundamentals Flashcards

1
Q

What type of firemain is onboard?

A

Vertical Offset Loop

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many AFFF (Aqueous film forming foam) stations are onboard?

A

7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Where is AFFF Station #1?

A

Forward, stbd (2-45-1-Q)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where is AFFF Station #2?

A

Forward of Repair 5S, stbd, (2-80-1-Q)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where is AFFF Station #3?

A

Forward of Main 2, port, (2-107-2-Q)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Where is AFFF Station #4?

A

Stbd, (2-110-1-Q)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Where is AFFF Station #5?

A

Stbd, (2-128-1-Q)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Where is AFFF Station #6?

A

Stbd, (2-184-1-Q)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where is AFFF Station #7?

A

Port, (2-184-2-Q)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the tank size for AFFF Stations?

A

1,295 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Where is the reserve tank location and size?

A

2nd deck, stbd, aft of Supply Office (2-27-1-Q)

2,115 gallons

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where is secondary CCS located?

A

Just aft of Repair 3S (2-169-1-Q)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How many fire pumps are onboard?

A

10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where is Fire Pump 1?

A

VCHT Pump Room 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Where is Fire Pump 2 and 3?

A

Aux 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Where is Fire Pump 4 and 5?

A

Main 1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Where is Fire Pump 6 and 7?

A

Aux 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Where is Fire Pump 8?

A

Main 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Where is Fire Pump 9 and 10 located?

A

Aux 3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

What is the Rating for the Fire Pumps?

A

1000 gallons/minute

200 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

How many P-100 portable fire fighting systems are onboard?

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Where is P-100 #1?

A

2nd deck, forward, stbd, by ATM machine, in P-way (2-33-0-L)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Where is P-100 #2?

A

2 – 2nd deck, in front of AFFF station 7, port, in P-way (2-173-2-L)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Where is P-100 #3?

A

1st deck, port, prior to going on flight deck, in P-way (1-122-2-L)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Where is P-100 #4?

A

2nd deck, stbd, in front of AFFF station 6, in P-way (2-173-1-L)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

How many decontamination stations are onboard?

A

4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Where is Decon 1?

A

2nd deck, port, by shore power switchboards (2-30-2-L)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

Where is Decon 2?

A

1st deck, port, by cargo elevator 1 (1-64-2-L)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

Where is Decon 3?

A

01 level, boat valley entrance (01-95-3-L)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

Where is Decon 4?

A

1st deck, stbd, in helo hanger (1-110-5-L)

31
Q

What actuates the HFP system?

A

Actuated by 5 lb CO2 bottle.

32
Q

What is the purpose of the 30 second delay when lighting off the HFP system?

A

A 30 second time delay is provided to allow ventilation to properly shutdown.

33
Q

What is the purpose of the HFP System?

A

Provide remote firefighting ability from outside space. Extinguishes fires in specific equipment areas where an electrically non-conductive agent is required. Decomposes and becomes toxic at 1200 degrees F

34
Q

How does HFP affect fire?

A

HFP interrupts the fires Uninhibited Chemical Chain Reaction (UCCR)

35
Q

What does HFP stand for?

A

Heptaflouropropane

36
Q

Which spaces are protected by HFP system?

A

Paint Locker (4-10-2-K)
Hazardous Material Locker
Flammable Liquid Store Room (6-18-2-K)
HAZMAT Equipment Room and Storeroom (2-134-1-K)
Cargo Store Room Petroleum, Oil and Lubricants (4-133-2-A)

37
Q

How many repair lockers are onboard?

A

6

38
Q

Where is Repair Locker 2?

A

2nd deck, forward, port side (2-36-2-Q)

39
Q

Where is Repair Locker 3?

A

2nd deck, aft of ER09 shop (2-159-2-Q)

40
Q

Where is Repair Locker 4?

A

1st deck, port side (1-64-10-Q)

41
Q

Where is Repair Locker 5 Port?

A

2nd deck, mid-ship, aft of small arm magazine (2-95-2-Q)

42
Q

Where is Repair Locker 5 Stbd?

A

2nd deck, mid-ship, (2-83-1-Q)

43
Q

How many Damage Control Unit Patrol Stations (DCUPS) are onboard?

A

2

44
Q

Where are the DCUPS located?

A

21 – 2nd deck, stbd, by shore power switchboards (2-28-1-C)

41 – 02 level, port, forward of CSMC (02-39-2-C)

45
Q

What is the rating of each fire pump?

A

1000 gallons / minute

46
Q

Who is the Damage Control Officer?

A

LCDR Gorum

47
Q

How many Main Drainage Eductors are onboard?

A

5

48
Q

Where are the Main Drainage Eductors located?

A
1 – Aux 1
2 – Main 1
3 – Aux 2
4 – Main 2
5 – Aux 3
49
Q

What is the rating of each main drainage eductor?

A

600 gallons / minute

50
Q

What is the proper set up sequence for the main drainage eductor?

A

Discharge, Firemain, Suction (DFS)

51
Q

How many Secondary Drainage Eductors are onboard?

A

11

52
Q

Where are the secondary drainage eductors located and what is their rating?

A

Chain locker – 100 gallons / minute

Flammable locker – 100 gallons / minute

MMR 1 Refer Stowage Drain Tank – 20 gallons / minute

Port and Stbd Stern Gate Machinery Room – 100 gallons / minute

VLS – 750 gallons / minute

Port and Stbd Stern Gate Ram Room – 100 gallons / minute

Steering Gear Ram Room – 200 gallons / minute

MOGAS Ready Room – 100 gallons / minute

Port & Stbd Forward Well Deck Ramp – 100 gallons / minute

53
Q

How are the Repair Lockers numbered?

A

Repair 2, 3 port, 3 stbd, 4, 5 port, 5 stbd

54
Q

What spaces are protected by the Water Mist System?

A
MMR 1
MMR 2
AMR 1 
AMR 2 
AMR 3
55
Q

What is the purpose of the Water Mist System?

A

Provide remote firefighting ability to main spaces. Provide a fine mist of water, reducing the oxygen levels, suppressing the fire

56
Q

How many Water Mist Pump Rooms are there and where are they located?

A

Water Mist Pump Room #1 (5-48-2-E)

Water Mist Pump Room #2 (5-128-3-E)

57
Q

Who is the Command Fire Marshal?

A

DCCS Tanner

58
Q

Where are fire pumps 6 & 7 located?

A

AUX 2

59
Q

What is the proper set up sequence of the Main and Secondary Drainage Eductors?

A

Discharge, Firemain, Suction (DFS)

60
Q

Where are fire pumps 2 & 3 located?

A

Aux 1

61
Q

How are the Damage Control Unit Patrol Stations numbered?

A

21 and 41

62
Q

Who is the Damage Control Assistant?

A

ENS SHEPARD

63
Q

Where is fire pump 1 located?

A

Forward VCHT

64
Q

How many Main Drainage Eductors are onboard?

A

5

65
Q

Where are fire pumps 9 and 10 located?

A

Aux 3

66
Q

What is the size of the AFFF reserve tank?

A

1295 gallons

67
Q

Who is the Gas Free Engineer?

A

ENS SHEPARD

68
Q

What is the rating of the majority of the Secondary Drainage Eductors?

A

100 gallons / minute

69
Q

Where are fire pumps 4 and 5 located?

A

Main 1

70
Q

What temperature does HFP become toxic?

A

Decomposes and becomes toxic at 1200 degrees F

71
Q

Where is fire pump 8 located?

A

Main 2

72
Q

What is the purpose of the Water Mist and HFP fire fighting systems?

A

Provide remote fire fighting capabilities

73
Q

How many Water Mist pump rooms are onboard?

A

2

74
Q

What side of the ship are the majority of AFFF stations located?

A

Stbd