What is a Class Alpha fire?
And what is the preferred way to extinguish it?
Combustible materials
Water/ CO2
What is a Class Bravo fire?
What is the preferred agent way to extinguish?
Flammable liquids
AFFF
What is a class Charlie fire?
What is the preferred agent to extinguish?
Electrical
CO2
What is a class delta fire?
What is the preferred agent to extinguish?
Burning metal
Water mist/ jettison
What is overhaul?
Use thermal imager to resurvey space and look for residual hot spots or fires
How do you overhaul a class A fire?
Use a rake or solid stream
How do you overhaul a class B fire?
Use AFFF or PKP
How do you overhaul a class C fire?
Use CO2, ensure affected equipment is no longer energized
How do you overhaul a class D fire?
Use cooling agents (water mist, CO2)
How do you overhaul a main space fire?
Assessment team walks all levels of space
What do you do when a weapon is on fire?
The priority is cool the weapon, request additional hose team to combat the casualty.
What do you do when there is a fire in a CBR environment?
Priority is the fire, hose team dresses out in firefighting gear
What does SCBA stand for?
SELF-Contained breathing Apparatus
What are 2 sizes of the SCBA?
What is it pressurized at?
30 min, 45 min
4500
Who wears 30 min bottle?
Investigators and electricians
What is the thermal imager onboard called?
K-90 Talisman
Who uses the K-90 talisman and what can it read and what can it not see thru?
Team leader
Heat signatures
Aqueous materials
How many patterns on a vari-nozzle? And what are the patterns
4 Wide V Narrow V Solid stream Flush
What is wide V used for?
Used has a heat shield and water fog
What is narrow v used for?
Standard firefighting pattern
What is solid stream used for?
Used for overhaul
What is flush used for?
To get debris out of nozzle
What is p-100 rated at and what is it used for and runs on?
100 GPM @ 83 PSI
used for dewatering
Runs on JP-5
What are 2 types of portable educators?
Peri-jet, S type