Who is the DCO
Chief Engineer, CAPT Select Lannaman
Who is the DCA
CDR Select Payne
Who is the ADCA
CWO2 Franklin
Who is the ship’s Fire Marshall
LT Sales
What does DCTT stand for
Damage Control Training Team
Who is the DCTT leader
XO
Who is the DCTT Coordinator
Fire Marshal
Who are the 4 people on the Rapid Response Team
Fire Marshal, Electrician, 2 Investigators, Boundary Men
What is the job of the Rapid Response Team
Go straight to the scene and take appropriate actions
How many people are assigned to the Rapid Response Team
4
If you need to validate fittings on your CCOL where would you look
DC Books
What book is used for combating fires in main spaces
Main Space Fire Doctrine
If you need to keep a fitting open for an extended period of time what do you do
Log it in the Material Conditions Violation section of the Closure Log
What do yo use to inventory the kits
Allowance Equipage List (AEL)
What is the Primary purpose of eductors
To remove greasy, oily and contaminated water
Who is the DCTT Coordinator
Fire Marshal
How many people are assigned to the Rapid Response Team
4
What is the responsibility of the Rescue and Assistance Team
Back up to the At Sea Fire Party
What book is used for combating fires in main spaces
Main Space Fire Doctrine
How long can you keep the Closure Log opened
Not longer then 24 hours
If you cannot secure a fitting what do you do
Log it in the OOC Log
Who maintains the Closure Log
EWS inport, DCWS underway
Who reviews the closure log
Fire Marshal, Duty Fire Marshal, ADCA, DCA, EDO
Name one side of the fire triangle
Oxygen, Fuel, Heat
Describe Alpha, Bravo, Charlie, Delta fires
- Alpha- Materials that leave ashes
- Bravo- Hazmat and Fuel
- Charlie- Electrical
- Delta- Combustible Metals
What is the flashpoint of JP-5
140 Degrees
What are the 4 stages of a fire
Growth, Flashover, Fully Developed, Decay
If DC Cenral goes down, where is secondary central located
Repair locker 3
How many repair lockers do we have
10
Where are the repair lockers located
- 1A HB3
- 1B HB2
- 1F HB1
- 2 Deck Berthing
- 3 Male Supply Berthing
- 4 Next to security dispatch
- 5 Aft mess decks
- 7A O3 aft
- 7B Next to CO inport cabin
- 7F O3 forward
PKP comes in 2 sizes, what are they
18 lb and 27 lb
What does PKP stand for
Pruple K Powder
What is the effective range of an 18lb and 27lb PKP Extinguisher
!8(19 feet) 27(21 feet)
How does PKP extinguish a fire
Interrupts the chemical reaction
What type of Fires does PKP primarily put out
Bravo
What is the effective range of a CO2 extinguisher
4-6 feet
In continuous operation, how long does the 15 pound CO2 extinguisher last
40 seconds
Before you squeeze the lever to release the CO2, what should you do
Ground the cylinder to the deck
Why do you ground the CO2 cylinder
Avoid shock from the static electricity
How does CO2 extinguish a fire
Displaces the oxygen
What are the portable AFFF bottles used for
Grease and Small Bravo Fires
What is the distance of a portable AFFF bottle
15 feet and decreases with use
How do you know that the AFFF bottle is good
Needle should be in the green
How much AFFF is in the bottle
2 Gallons
What are the 2 sizes of metal shores
3-5 feet, 6-11 feet
What is the vertical load strenght of a 3 foot to 5 foot metal shore
3 feet- 20,000 lb, 5 feet- 12,000
What is the vertical load strenght of a 6 foot to 11 foot metal shore
6 feet- 20,000 lb, 11 feet- 6,000
Name one type of shoring
I, K, H
What is the strongest type of shoring
I type
What is the weakest type of shoring
H type
What book is used for combating Fires in Main Spaces
Repair Party Manual
What are the best wods to use for shoring, plugs and wedges
Douglas Fur and Yellow Pine
Why do we use Douglas Fur and Yellow Pine
It expands as it absorbs water
How many types of Pipe Patches are there
4
What are the types of Pipe Patches
Soft, Banding, EWARP, Jubilee
What holds up to 100 psi only
Jubilee
What is the Max temperature on a pipe you can appply EWARP
300 Degrees
What is the Max PSI of the others
150 PSI
What activates the halon board
Pulling the activation lever on the 5lb CO2 bottle
What does NFTI stand for
Naval Firefighting Thermal Imager
What powers the NFTI
10 AA batteries
Is the NiMH battery pack rechargeable
Yes
How do you know the NFTI is fully charged
10 bars on the bottom left corner
Name 5 kits found in a Repair Locker
Investigator, Electrician, Comms, Pipe Patching and Shoring
What does PECU stand for
Portable Exothermic Cutting Unit
Where is the PECU located
Repair Lockers
Who operates the PECU
Access/Overhaul Person
What are the cutting rods made of
Carbon Steel
What size battery does the PECU use
12 Volt
What are two types of portable eductors
Derbyshire and Peri Jet
What is the primary use of the P-100
Firefighting, secondary dewatering
How many P-100 are onboard
2
How many pumps run list control
2
Where are the P-100 located
HB1 mooring room, HB2 Admirals P-way
What cools the P-100 while is being use
Air
What is the maximum lift that a P-100 pump can take suction
20 feet
What type of fuel does the P-100 utilize
JP-5
What does ESP stand for
Electrical Submersible Pump
ESP is not desgined for pumping what types of liquids
Gasoline, Heavy Oils or Hot Water
What is the maximum static head for the ESP
70 feet
When using the ESP’s in tandem which pump do you start first
The bottom one
What is he purpose of the ram fan
To desmoke a space containing explosive gases
What powers the ram fan
Firemain
What safety precautions must be followed prior to energizing the ram fan
Ground it
What maximum number of trunks can you put on the suction side
3
How many on the discharge side
3
How are the Trunks connected
Latching clamps on the ends of the trunks
How many cubic feet per minute does the Ram Fan move
2000
Where can you use the Box Fan for desmoking operations
Spaces adjacent to weatherdeck/Hanger bay areas
What powers the Box Fan
Electricity
How much air does the Box Fan move
3200 Cubic Feet per Second
Who is in charge of the Repair Locker during a casualty
Locker Leader
Who is reponsible for handling electrical damage
Repair Electrician
Who is overall in charge of a casualty inside the effected space
Team Leader
Who carries the NFTI
Team Leader
How long will the OCENCO EEBD last during use
10 minutes
Who wears a 30 minute bottle/45 minute SCBA
30 Investigator, Boundary men, Scene Leader. 45 Team Leader, Hose Team
What percent of air do you have left on your SCBA when the vibra-alrt goes off
25%
What are the 2 types of alarms on the SCBA when your air is low
Bell and Vibrant Alarm
What are the SCBA bottles made of
Carbon Fiber
What should you do once you take out an SCBA prior to use
Ensure that it is not below 4000 PSI
The nozzle has 3 positions on it, what are they
Solid Stream (Over Haul), High Velocity (Fire Fighting), Low Velocity (Cooling and Relief) and Flush
Which boundary should be set the fastest during a fire
The above
Who determines a space is safe to enter without breathing
DCA (At sea), Enigneering Duty Officer (Inport)
What person on the fire party conducts atmospheric testing
Fire Marshal/Gas Free Engineer
What ar the four principles of investigation
Thoroughly, Caustiously, Report, Repeat
Air escaping from air test fitting indicates what kind of damage
Flooding
Air sucking in the test fitting indicates what kind of damage
Fire
What is the Tap Test
Check a bulkhead or Water Tight Door for flooding
What does APC stand for
Aqueous Potassium Carbonate
What is APC system used for
Protection for galley deep fat fryers and their exhaust system
How does APC extinguish a fire
Combines with the hot cooking oil to cut the oxygen out
Where can you find APC
Galley
How many halon boards do we have
9
What does 30 second time delay mean
Unmanned Space
Name one space where we have a halon board
Fwd/Aft EDG, Pump Room #2 and #3, Shaft Alleys (Engineering Spaces)
Lights on the halon board
White: Power Available, Amber: Halon Activated, Red: Halon Discharge, Green: Vent Damper
How many CO2 fix flooding systems do we have
4
How do you activate CO2 fix flooding
Pulling the T Shaped handle until you see red on cable
Name one space the CO2 fix flooding can be found
Hazmat Storerooms
How many recharge stations do we have
8
Name the recharge stations
1A, 1B(2), 1F, 2, 3, 7B, 7F
If we lose HP air, what do we use to fil the SCBA bottles
Emergency Breathing Air Compressor (EBAC)
How many EBAC’s do we have
2
Name the location of the EBAC’s
Foward Starboard and Aft next to the jet shop
What is the purpose of list control
To correct list, so planes can land
How many list control tanks do we have
10
How many places can you operate List Control and where
- DC Central and 4A Shaft Alley
What type of water is in list control tanks
Potable Water
Where are the list control pumps located
4A Shaft Alley
What is the GPM for the list control pumps
1800 GPM
Who operates list control
Damage Control Watch Supervisor (DCWS)
What 2 list control tanks hold the most
113 and 165
What do we use to determine the list
Clinometer
What type of Firemain do we have
Composite Loop
How many fire pumps do we have
- 19 Electrical, 4 Steam
If there is a rupture in the Firemain how do you keep it active in that section of the loop
Rig a 2 1/2 jumpers hose between the 2 closest fire stations by removing the Y-gate
How many main drainage eductors do we have
13
How do you operate the drainage system to pump over the side
Discharge Valve, Firemain Valve, Suction Valve
How do you secure the drainage system
Suction Valve, Firemain Valve, Discharge Valve
What is the purpose of main drainage
Pump oil waste or water out of the bilges
How many HICAP AFFF stations do we have
20
Where are the HICAP AFFF stations located
2nd Deck
How many mixing stations do we have
21
Where are the mixing stations located
On the O3 level
What’s so special about mixing station 21
Bomb Farm
What are the tanks made of
90/10 Copper Nichol Alloy
How much AFFF is in the tanks
600 gallons
How many stations have balance pumps
16
How many stations have injection pumps
20
What stations are injection pump only
1, 2, 11, 12
What is the mixing ration for Firemain and AFFF
94%, 6%
What is the GPM for the injection pump
60 GPM
What is the GPM for the balance proportion pump
65 GPM
What is the Pancake Valve
Regulates AFFF and Firemain
What must you have to ensure the Pancake Valve station will operate
Firemain Pressure
What is the minimum to maximum Firemain pressure needed
125-170 PSI
Purpose of SOPV
Energize the station
What does SOPV stand for
Solenoid Operated Pilot Valve
How many volts in the SOPV
440 volts
How many reserve tanks do we have
2
How much AFFF concentrate is in the Transfer tank
3600 gallons
Name the location for the Transfer tanks
HB1 Port, HB3 Starboard
Name the location where a reserve pump is located
6, 13
What is the GPM for the reserve pumps
360 GPM
How many ways can you activate the reserve stations
2 ways. Locally and Remotely
Can be activated from: Bridge panel, pri fly panel, hose reels in the catwalks, hangar bay sprinklers, hose reels in the hangar bay, weapons elevators, main space hose reels, 2nd deck hose reels, bilge and over head sprinklers
How many Sound power phone circuits are there
5
What is the circuit linking DC Central to the Repair Lockers
2JZ
What is the primary use of communication from the Locker to the Scene
Hydra
What is the secondary use of communication from the Locker to the Scene
Orange Pumpkin Line
What is used to keep a hard copy record of events of a casualty
Message blanks and DC Charts
How do we plot damage
DCAMS and DC Charts
What does a circle on a message blank mean
Casualty Contained
Where can you find a list with standard message writing
On the back of the message blank
What is MPE
Maximum Permissible Exposure
Who sets MPE
CO
What does MOPP stand for
Mission Oriented Protective Posture
What is the primary protection during chemical, biological and radiological attack
Gas Mask
Whay type of threads does the C-2 cannister have
NATO
What does the ACPG stand for
Advance Chemical Protective Garment
What is the difference between DON and DOFF
DON to put on. DOFF to remove
At what stage do you remove your ACPG smock
Stage 1
At what stage do you remove the gloves and liners
Stage 3
What is the purpose of the M-256A1 kit
Used to detect nerve, blood, blister in vapor form
What does RSDL stand for
Reactive Skin Decontamination Lotion
What is the RSDL kit for
Decontaminate area of the skin
The RSDL kit contains how many pouches and what color are they
- Color is Green. Blue is for training
How long must the RSDL remain on the skin after applied
At least 2 minutes
Each packet of the RSDL contains a pad that has how much lotion in it
21 ml
What is the storage temperature of the RSDL
15 to 30 Degrees Celcius
What color does the M-9 paper turn when an agent is present
Red
At what MOPP level is M-8 paper posted
MOPP level 2
How many MOPP levels do we have
5
What MOPP level are we at right now
1
What are the MOPP levels
0, 1, 2 ,3 ,4
What is IPDS
Improved Point Detection System
What is CDU
Control Display Unit (DC Central)
What is RDU
Remote Display Unit (Bridge)
Difference between CDU and RDU
Bridge doesn’t have controls just the one in central
What type of system is the IPDS
Fixed (Stationary)
What does IPDS detect
Nerve (G and H) series and blister
What is the difference between the CCA and DS
Contaminated Control Area: Take your ACPG suit off. Decon Station: Take coverals and shower
What is HTH
High Test Hypochlorite
How many CCA’s do we have
- (HB1,HB3)
How many DS do we have
4 (Next to Repair Locker 2, Male Weapons Berthing, Female Chiefs Head, Reactor Male Berthing)