Core Spray Flashcards

1
Q

What is the initiation signal for core spray?

A

LOCA

LL3 OR RPV <410# DW >1.7#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When does the core spray min flow valve (F031) open and close?

A

Normally open

Open when pump breaker closed and <500gpm

Close when pump breaker closed and >1500gpm

if manually positioned while pump breaker closed will return to position dictacted by flow rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

At what RPV pressure is core spray able to inject?

A

300psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

WHen does the Core spray injection valve (F005) open?

A

RPV pressur <410psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the difference between an auto start and a test start for core spray room coolers?

A

Auto _ start off pump breaker closure - fan starts and SW supply opens

Test - fan start but no service water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What will trip a core spray pump?

A

Electrical only.

overcurrent UV

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the inboard core spray injection valve normal alignment and when does it auto and manually reposition?

A

Normally closed

Can be manually opened if RPV pressure <410psi or Outboard injection valve is full closed

Auto opens on a core spray initiation (after STR timer) when RPV pressure <410psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the outboard core spray injection valve normal alignment and when does it auto and manually reposition?

A

Normally open

If closed, can only manually open if the inboard F005 is closed

Receives open signal on CS initiation (after STR timer) and cannot be closed with a CS signal present