Core Spray Flashcards
What is the initiation signal for core spray?
LOCA
LL3 OR RPV <410# DW >1.7#
When does the core spray min flow valve (F031) open and close?
Normally open
Open when pump breaker closed and <500gpm
Close when pump breaker closed and >1500gpm
if manually positioned while pump breaker closed will return to position dictacted by flow rate
At what RPV pressure is core spray able to inject?
300psi
WHen does the Core spray injection valve (F005) open?
RPV pressur <410psi
What is the difference between an auto start and a test start for core spray room coolers?
Auto _ start off pump breaker closure - fan starts and SW supply opens
Test - fan start but no service water
What will trip a core spray pump?
Electrical only.
overcurrent UV
What is the inboard core spray injection valve normal alignment and when does it auto and manually reposition?
Normally closed
Can be manually opened if RPV pressure <410psi or Outboard injection valve is full closed
Auto opens on a core spray initiation (after STR timer) when RPV pressure <410psi
What is the outboard core spray injection valve normal alignment and when does it auto and manually reposition?
Normally open
If closed, can only manually open if the inboard F005 is closed
Receives open signal on CS initiation (after STR timer) and cannot be closed with a CS signal present