Company Hydro-Exemption Flashcards
1
Q
What testing does company require on shell-to-bottom welds for hydro-exemption?
A
- Visual root pass
- MT/PT root pass
- Pen Oil test root pass
- Visual Final pass
- MT/PT Final Pass
- Pen oil or vacuum box final pass
2
Q
What testing does company require on bottom welds within critical zone for hydro-exemption?
A
- visual root pass
- mt/pt root pass
- visual final pass
- mt/pt final pass
- Ut final pass (regarding annular butt joints)
- vacuum box final pass
3
Q
What testing does company require on bottom welds outside the critical zone for hydro-exemption?
A
- mt/pt final pass
- vacuum box or tracer gas after final pass
4
Q
What testing does company require on shell plate to shell plate welds (less than 1” thick) for hydro-exemption?
A
- visual final
- 100% RT of vertical and horizontal welds
5
Q
What testing does company require on shell welds for reinforcing plate-to-nozzle neck and nozzle neck-to-shell joints (API 653 12.3.3.3.6) for hydro-exemption?
A
- complete penetration and fusion
- mt/pt back-gouged surface of root pass
- visual final pass
- mt/pt final pass
- ut shearwave final pass
6
Q
What testing does company require on brittle facture requirements for hydro-exemption?
A
- new and old material shall meet DMT requirements or be exempt per API 653 section 5.