What testing does company require on shell-to-bottom welds for hydro-exemption?

A
  1. Visual root pass
  2. MT/PT root pass
  3. Pen Oil test root pass
  4. Visual Final pass
  5. MT/PT Final Pass
  6. Pen oil or vacuum box final pass
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What testing does company require on bottom welds within critical zone for hydro-exemption?

A
  1. visual root pass
  2. mt/pt root pass
  3. visual final pass
  4. mt/pt final pass
  5. Ut final pass (regarding annular butt joints)
  6. vacuum box final pass
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What testing does company require on bottom welds outside the critical zone for hydro-exemption?

A
  1. mt/pt final pass
  2. vacuum box or tracer gas after final pass
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What testing does company require on shell plate to shell plate welds (less than 1” thick) for hydro-exemption?

A
  1. visual final
  2. 100% RT of vertical and horizontal welds
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What testing does company require on shell welds for reinforcing plate-to-nozzle neck and nozzle neck-to-shell joints (API 653 12.3.3.3.6) for hydro-exemption?

A
  1. complete penetration and fusion
  2. mt/pt back-gouged surface of root pass
  3. visual final pass
  4. mt/pt final pass
  5. ut shearwave final pass
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What testing does company require on brittle facture requirements for hydro-exemption?

A
  1. new and old material shall meet DMT requirements or be exempt per API 653 section 5.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly