Chapter 6.80 - Fire Protection Flashcards
What happens when the engine fire handle is pulled?
3 - Closes both engine and spar fuel valves
3 - Closes the engine bleed air valve
3 - Closes the hydraulic shutoff valve
2 - Disarms the engine driven hydraulic pump LOW PRESSURE light
2 - Disarms the thrust reverser
1 - Arms the fire bottle squibs
0 - Opens the generator field
What happens when the APU fire handle is pulled?
3 - Closes the APU fuel valve
3 - Closes the APU bleed air valve
3 - Closes the APU inlet door
1 - Arms the APU fire bottle squib
0 - Opens the generator field
If the FAULT light does not illuminate during FAULT/INOP test what does this indicate?
Failure of the fault detector to be able to detect a fault
What does an illuminated FAULT light indicate?
Illuminated APU DET INOP light?
Loss of fire detection on at least one engine
Loss of APU fire detection
If the amber FAULT light comes on during the OVHT/FIRE test what does this indicate?
Can you isolate the problem further?
Indicates a failure of at least one loop
Move the OVHT DET switches to A and B one at a time to isolate the faulty loop
What does an amber DETECTOR FAULT light indicate on the cargo fire panel?
One or more of the selected detector loop(s) in either cargo compartment has failed