Chapter 5: Electrical Flashcards
IDG (Integrated Drive Generator)
115 VAC, 40 kVA, 400 Hz, 3-phase
Constant Speed Drive coupled to an electrical generator, controlled by GCU (Generator Control Unit)
EICAS message and Amber Light on Associated IDG if:
Oil temperature > 335 F +/- 10 F
Oil pressure < 140 psi +/- 25 psi
Automatic Disconnect if oil temperature > 366 F
Manual Disconnect: Hold “DISC” for 1 second (NOT more than 3 seconds)
Cannot reconnect after disconnection
APU (Auxillary Power Unit)
115 VAC, 40 kVA, 400 Hz, 3-phase
Can provide pneumatic power for ECS and engine starts
RAT (Ram Air Turbine)
115 VAC, 15 kVA, 400 Hz, 3-phase
Powers AC ESS BUS
Takes 8 seconds to spin up to speed
Must be > 130 KIAS
Batteries
NiCd (Nickel-Cadmium) or LSA (Lead Solid Acid) 22.8 VDC, 27A, 27 Ah Max Temperature: 70 C Lower than 22V => Need to be recharged Lower than 21V => Call maintenance
TRU (Transformer Rectifier Unit)
Converts 115 VAC to 28 VDC
Rated for 300 A
Electrical Emergency
AC power sources are not powering AC busses
Batteries only last 10 minutes
Source Priority
Respective IDG
APU
AC GPU
Opposite IDG
DC GPU Voltage Limits
24-32 VDC
SPDA Locations
SPDA 1: Forward Electronics Bay
SPDA 2: Center Electronics Bay
HOT BATT BUS 1 Components
- Courtesy/Service Lights Forward
- DC Ceiling Lights
- Engine 1 Oil Level Indication
- Engine 1A Fire Extinguish
- Engine 2A Fire Extinguish
- Engine Fuel SOV 1
- Hydraulic SOV 1
HOT BATT BUS 2 Components
- Engine 2 Oil Indication
- Engine 1B Fire Extinguish
- Engine 2B Fire Extinguish
- Engine Fuel SOV 2
- Hydraulic SOV 2
- Panel Refuel 3
- Water and Waste System Controller PWR 3
- CMC
STBY AC BUS Components
Engine 1 Exciter 1A
Engine 2 Exciter 2A
AC ESS BUS Components
AC Fuel Pump 2A
ACMP 3A
SF-ACE 1 Flap Ch 1 AC Feed
SF-ACE 2 Slat Ch 2 AC Feed
Electrical System Distribution
Power Source => AC/DC Busses => SPDA => Components
SPDA has built-in circuit breakers
MAUs can define complex logic for specific components
Some components have alternate direct connection to AC/DC Bus for redundancy in case of SPDA/MAU failure
Load Shed
When power demands exceed system limit, SPDA commands load shedding of:
- Galleys
- Righthand windshield heating