Chapter 3 Self Test Flashcards
(017) 2. How many option does the level 1 disc contain?
Nine
(017) 1. What does level 1 testing do?
It verifies the operational capability of the missile and performs limited fault isolation.
(017) 3. Which test option is used for establishing new calibration constants for the INE?
Level 1 with INE autocalibration
(017) 4. Which test option is used to verify repair directed by level 1?
Level 1 selected module
(017) 5. What does the missile radar altimeter test assembly self-test option do?
Provides an internal test of the MRATA
(017) 6. Which module does not allow repeat testing during a level 1 fault?
CMRA module
(018) 1. Which task must be performed following a cruise missile engine change?
Engine fuel prime
(018) 2. Which piece of equipment is used to perform the engine fuel prime?
Air purge and pressurizing unit (APPU)
(018) 3. What critical check is performed before starting the engine fuel prime?
Missile safe status check
(019) 1. What term is applied to components that might fail to function properly when exposed to a nuclear environment?
Hardness critical
(019) 2. A nuclear environment includes nuclear radiation, electro-magnetic pulse and what other component?
Thermal radiation
(019) 3. What actions should be avoided to prevent damage to equipment and degrade system hardness?
Excess bending and/or pulling of electrical cables and shields during maintenance operation.
(019) 4. What symbol located within technical order instructions identifies hardness critical procedures?
HCP
(020) 1. What type of a system is used during fueling and defueling operations?
Closed-piping system with a nitrogen blanket
(020) 2. When is fuel conditioned through the fuel set?
Prior to fueling
(020) 3. Which TO is used when performing fueling and defueling operations?
21M-AGM86-31
(020) 4. How many degrees is the nose of the missile lifted during defueling operations?
4 degrees
(021) 1. Which TO coves composite material repairs?
21M-AGM86-2-1
(021) 2. What grade of sandpaper do you use when performing aluminum casting repair?
320 grit or finer
(021) 3. Concerning the cruise missile, what are captive fasteners primarily used for?
To secure the majority of the panels to the missile
(022) 1. Which two tasks are primarily involved when performing electrical repairs?
Splice removal and splice installation
(022) 2. Which TO contains splice removal and splice installation procedures?
21M-AGM86-2-1
(023) 1. When looking at a diagram to understand system operation, what does the diagram provide?
Provides a visual picture to show how components interact with each other.
(023) 2. Unless otherwise indicated, in which state does a wiring diagram show a circuit?
De-energized
(023) 3. What is the most important key to reading and understanding wiring diagrams?
The ability to read symbols
(023) 4. Which type of electrical diagram is designed to show you the point-to-point connections between components?
Wiring
(023) 5. When interpreting block diagrams, what makes it so useful?
They give a quick general view of the overall system.
(023) 6. Which type of diagram provides a deeper look by showing the components and connections that make up a single piece of equipment, or circuit within the equipment, in a straight line without regard for physical location or relationship?
Schematic diagram
(024) 1. What is defined as a step-by-step procedure for analyzing, locating, and correcting electrical malfunctions?
Electrical troubleshooting
(024) 2. What must you do before jumping to conclusions in order to successfully locate a fault?
Research the fault
(024) 3. When troubleshooting, who should you reference to help you isolate faults?
Supervisors and shop personnel
(024) 4. When trying to troubleshoot and isolate a fault, what basic things should you use at first?
Use your senses of hearing, sight, smell, and touch
(024) 5. When performing an operational check, what must you ensure are properly positioned?
Controls
(024) 6. What is the fourth step in the troubleshooting process?
Analyze the malfunction
(024) 7. After analyzing the malfunction, what is the first step in locating the fault?
Check out the easy fixes. Look for tripped circuit breakers, blown fuses and faulty power supplies.