ch 16 test quiz Flashcards
1” (25 mm) hose stored on a hose reel is __________ hose.
booster
Which hose line is stored on an engine connected to a discharge and equipped with a nozzle for immediate deployment?
Preconnect
The function of a standpipe system is to provide:
a water supply for interior attack lines.
Standard operating procedures generally require that an attack line be connected to a standpipe system outlet:
one floor below the fire floor
For which preconnected hose load does the fire fighter shoulder part of the load, with the hose deploying off the top of that load as the fire fighter advances?
Minuteman
Which preconnected hose load forms an S-shape in the hose bed?
Triple layer
When using a standpipe connection in a stairwell, how should the hose be arranged?
Up the stairwell toward the floor above the fire
How should fire fighters space themselves when advancing an uncharged line up a ladder?
One firefighter on each ladder section
A hose line is advanced to a building to attack a fire in a(n) __________ attack.
offensive
An engine lays hose from a water source to the fire scene in a __________ lay
forward
Which is an advantage of a forward lay?
Places the attack engine and its equipment close to the fire
When charging a supply line at a hydrant, the fire fighter should:
avoid standing between the hose line and the hydrant.
The end of the hose bed closest to the apparatus cab is the:
front
A short fold in a supply hose load that prevents a coupling from flipping around when the hose is being laid out is a:
dutchman
A soft sleeve hose is used to connect a pumper to a:
pressurized water source
1” (25 mm) hose stored on a hose reel is __________ hose.1
booster
Which hose line is stored on an engine connected to a discharge and equipped with a nozzle for immediate deployment?
Preconnect
Which is one of the three most common loads for preconnected attack lines?
Minuteman
The function of a standpipe system is to provide:
a water supply for interior attack lines.
Standard operating procedures generally require that an attack line be connected to a standpipe system outlet:
one floor below the fire floor.
For which preconnected hose load does the fire fighter shoulder part of the load, with the hose deploying off the top of that load as the fire fighter advances?
Minuteman
Which statement is correct concerning the triple-layer load?
The entire load must be on the ground before the nozzle can be advanced.
Which preconnected hose load forms an S-shape in the hose bed?
Triple layer
Which attack line load is particularly useful when there is a long distance between the engine and the fire?
Wyed lines