Ch. 13 Private Dwellings Flashcards

1
Q

Most serious design defect in multistory homes is:

A

Lack of enclosed stairway

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

2nd major problem (PDs)

- after open stairway

A

Lack of code requirements for interior finishes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Proper position for first engine is:

A

Just PAST fire bldg

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Ledger board sign of:

A

Balloon frame construction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Majority of fire in private dwellings (PDs) is where

A

Below the 2nd story

-either cellar or 1st floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Fire deaths in private dwellings (PDs)

A

More than 70%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

PDs firefighting activities (4)

A

Supply
Stretch charged line to protect bedroom exits
VES of ALL areas
Extinguish fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Second line assignment

A

Backup-same location as first
If needed, assist first and third line brought in as backup
If not needed, covers floor above fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

By far the fastest method of applying water (PDs)

A

Inline stretch of LDH, from hydrant into the fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Serious cellar fire and suspect balloon framing.

Outside wall, tear off molding, punch a hole and find 2x4 lying flat, this is a plate and _____________.

A

Balloon framing IS NOT present

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

If fire in balloon frame, 3 lines:

A

First to cellar
Second back up first
Third goes to top floor or attic

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Exceptions to roof vent with lower floor fires (2)

A

Cellar or basement fire in balloon-frame house
Lower-floor fire vents out window and ignites combustible siding, extending up eaves (most serious-asphalt/gasoline siding)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

PDs are primarily constructed with __________. These designed to shed snow better than flat, so joists can be ________. So ________ is common.

A

Peaked roofs
Of smaller size
2x6 in. lumber, 16-24 in. on center (maybe even 2x4 in older)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Old to new, roof sheathing in PDs

A

Furring strips, 1x2 in., 6 in. on center THEN
1x6 tongue and groove for sheathing
Latest is plywood or OSB for surface (same or LESS stability as T and G)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Slate vs Tile

A

Slate-scraped off
Tile-pried off with pointed tool
BOTH broken loose, sharp edged, heavy, extremely slick

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Venting roof

Safety again dictates __________ members (preferably experienced) be assigned to the task.

A

At least two

17
Q

Low pitch roofs

A

15-20 degrees

Power saw may be used

18
Q

High pitched roofs

A

Circular and chain saws extremely dangerous

If not operating from basket, use an axe

19
Q

Side of the peak in which the hole should be made is determined by the direction of the wind

A

Hole on downwind side-helps gas escape

Hole on upwind side-heat blown back toward HOSELINE crew

20
Q

(Roof)Weight that under fire conditions that could be straw that breaks camels back?

A

Older satellite dishes

21
Q

3 cuts for roof (PDs)

A

Standard cut-4x4 ft. cut, spans at least 2 joists and 14 nails
Quick cut-allows roof to hinge, plywood sheathing
Triangular opening-(from basket) spans several joists, difficult to cut, limited vent, advantage-member never sets foot on roof

22
Q

If solar panels are located directly over the best site for ventilation, must decide whether to: (2)

A

Move farther away from seat of fire OR
Place it on the other side of the peak
Conditions at scene must dictate this decision

23
Q

Most authorities recommend a hole of approximately ________ for private dwelling fires.

A

4 x 4 ft