Ch 10. Operating Fire Pumps Flashcards
What are the steps for putting the pump into operation?
1.Open tank to pump valve,
2.Open discharges to hose lines being used,
3. Open the valves fill hose with water, 4. Increase the throttle,
5. Once water is flowing adjust pressure, 6. Monitor all gauges
When the pump is an operation, what is the responsibility of the driver/operator if a flow meter is in use?
Adjust the throttle until the desired flow rate is achieved
What steps are necessary to transition from tank water to a water supply?
- Connect the supply line into inappropriate intake.
- Make the connection to the intake with the gate valve closed.
- Open the hydrant/supply line to supply water to the closed intake valve. Open bleeder valve to allow air to escape. Open intake.
Operating the pump with a residual pressure below ________ psi while being supplied by other apparatus is dangerous.
20 psi
Why must water supply systems (municipal) maintain a residual pressure of at least 20 psi?
Contamination from sources outside the main may occur at lower pressures.
This may cause the supply hose to collapse, interrupting the supply of water.
What are the least desirable hydrant locations?
Dead and hydrants
Why might a fire hydrant be too close to the incident to use?
Creates a safety hazard for apparatus and personnel
What type of Lay is the most direct method of supplementing hydrant pressure or performing drafting operations?
Reverse lay
What is a potential problem with choosing to make a long forward lay with large flow demands?
An additional pumper maybe needed, placed at the hydrant to make use of all available pressure
When should the driver/operator close the tank to pump valve?
After transitioning to an external water supply
What exceptional circumstance may require a series “pressure” setting of the transfer valve?
Supplying the upper floors of a high-rise
Percentage method:
What equation is used to determine available like volumes from a hydrant?
(SP-RP) 100 / SP = % drop
0-10% = 3x like volume
11-15% = 2x like volume
16-20% = 1x like volume
>20% = zero like volume
During prolonged pumping operations, a bypass circulator may not provide sufficient cooling. What additional measures maybe used to avoid overheating?
Open a discharge drain valve.
Partially opened the tank fill valve or tank to pump line.
Use hose line to spray pump panel.
When a pumper is connected to a hydrant and is not discharging water the pressure shown on the intake gauge is the _________?
Static pressure
Like available water: First Digit Method
What is the first digit method for calculating available water using psi and GPM

During drafting operations, the amount of friction loss is____________ to the amount of water moving through the hose or appliance.
Proportional