CCS Flashcards

1
Q

What are the Trips and Auto Starts for the CCS Pumps?

A

Trips:

  • Suction Pressure <25 psig for 5 seconds
  • Motor Electric Fault
  • Undervoltage

Auto Start:
Discharge Pressure <95 psig for 5 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the power supplies for the CCS Pumps?

A

CCS-P1A - SWG11
CCS-P1B - SWG13
CCS-P1C - SWG12

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the fail positions of the Temperature Control Valve and the Makeup Water Valve for CCS?

A

TCV - Max Cooling

M/U - Fails Open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What loads on CCS have no TCV associated with their HX?

A
  • Gen Leads Cooling(Bus Duct Cooling)
  • CWS Pumps
  • CNM-P1’s
  • CNM-P2’s
  • FWS-P1’s
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What loads on CCS have a TCV associated with their HX?

A

The following have a TCV on the CCS side of the HX:

  • EHC
  • OFG
  • TLO
  • GMH
  • Gen Exciter Coolers

GMC has a TCV in the GMC side of the HX

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What actions are required on a loss of CCS per SOP-14?

A
  • Scram

- Trip Turbine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the start limitations for restarting a CCS Pump?

A

CCS Pump start limitations are as follows:
• Two starts in one hour from ambient temperature. A one hour wait is required before additional start attempts.
• One start at rated temperature (obtained after 30 minute run). A one hour wait is required before additional start attempts.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the flow limitations for a CCS HX?

A

Limit of 8500 gpm to prevent tube vibration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are the CCS Pump operating limitations?

A

CCS Pump operating limitations are as follows:
• Maximum operating motor current is 58.5 amps.
• Minimum flow is 1,000 GPM.
• Maximum (runout) flow is 8,500 GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the max SWP D/P across a CCS HX?

A

10 psid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly