ARC Flashcards

1
Q

What system provides makeup water to the water seals on the ARC Pumps?

A

MWS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Above what level in the condenser are you not allowed to run the ARC Pumps?

A

Above 264’ (Suction is at 266’)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the max power that the ARC Pumps can be used at and why?

A

5% power, After that H2 becomes a concern, may damage stack on explosion…

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What will trip an ARC Pump?

A
  • MSL Rad Monitor >3 times NFPB
  • Low Seal water Flow (<10gpm for 10 Sec)
  • Under Voltage
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What happens on a MSL Hi/Hi(or INOP) Rad Alarm to the ARC System?

A
  • ARC Pumps Trip

- ARC-AOV105, ARC Pump Suction Line Isolation, will close

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the limit for operating at low power with low vacuum?

A

If vacuum is below 24.6”Hg, and Turbine load is less than 410MWe (30%), Trip the Turbine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly