Who is in responsible to check two floors below the fore floor for the suitability for staging ?
Fire attack
If there is an actual fire, the fire attack team can initiate fire attack. In this situation the officer now becomes a _______________ and remains in charge of the floor until relieved
Division supervisor
Staging is normally located how many floors below the fire ?
2
Where is the air operations branch director normally located ?
On the ground near the Helispot
During their response , Airborne Engine Companies are designated to the ___________________ until they are deployed and shall contact _______ for an assignment
HELCO or Air Ops Branch Director
IC
Base shall be established a minimum of ________ away from the incident structure
200 feet
What is the normal first alarm assignment for a reported fire in high rise structure fire ?
5 fire companies ( 2 trucks and 3 engines )
1 air borne engine company component ( task force )
1 ALS RA
1 BLS RA
1 EMS Captain
1 BC
1 squad ( specific first in districts )
In a high rise incident, a minimum of a ______-member initial fire attack team shall ascend to the reported floor
Four
What is the responsibility of the second in company in a high rise fire ?
Establishes lobby control
Officer becomes the IC
Supplying water to the building standpipe system will be the responsibility of the first arriving _____________, EXCEPT when the first and second arriving companies are single engine companies.
200 Series Engineer
Base may be established by available _________ from the first alarm assignment, or by a greater alarm company.
Engineers
In high rise fire incidents, a Rapid Intervention Company/Companies shall be located in, or proximity to, ________
Staging
What assignment may the SECOND arriving battalion chief be assigned to in a high rise fire ?
Division supervisor on fire floor
Air operations helispot should be at least _____ from the involved building
Helicopters should remain minimum of _____ from the involved building while in flight and away from the command post
1/2 mile
500 feet
A Division is a specific ____________ area, usually one floor in a high rise incident.
Group Supervisors manage a specific ___________ under the Incident Commander/ Operations Chief.
GEOGRAPHIC
FUNCTION
Who has the ultimate responsibility to authorize tor discontinue the use of elevators ?
The Incident Commander
Traditionally, occupant evacuation of the fire floor and the _____ floors above and below has been sufficient
Two
For our purposes, a high rise building is defined as a building which is over ____ in height, measured from ground level access to the floor level of the highest floor intended for occupant use.
75 feet
High rise buildings in the City are designed with __________ fire resistance between floors and around vertical openings
Two-hour
The third and by far the gravest threat to building occupants in high rise fires is _____________________
exposure to smoke and the products of combustion.
Department policy requires the Fire Attack Team take with them their _________, _______ , __________, _________, and a _________ if an elevator is used.
SCBA Pigtail High-rise hose pack Thermal imaging camera Fire extinguisher
Where can the interior lock box for FD use be located ?
Building lobby security post or fire control room
Who sets the stairwell climbing pace when ascending ?
The officer in charge
In addition to the key lock, some doors are held closed by a magnetic device requiring ____-pound pressure to overcome it. If the key unlocks the door, but it resists opening, give it a hard pull.
25
If the fire is reported to be ______________ the ____ floor, the stairwell SHALL be set and firefighters will walk to reach the fire floor
On or below the 6th floor
above the 6th floor you can use elevator
If used as a means of ascent, elevators should not be taken closer than ____ floors below the reported fire floor or two floors below the lowest alarm activated floor location.
Two
No more than ______ personnel with equipment is permitted in any elevator. This will prevent exceeding the weight capacity of the elevator.
Six
The PRESSURE REGULATING DEVICES control pressure, and assuming they are functioning properly, the volume of a give outlet can increase to supply more than one line, as long as the g.p.m. does not exceed the set limit which is normally ________
300 GPM
PRESSURE RESTRICTING DEVICES work by restricting to flow by how far the valve can be opened, thereby reducing the flow and the p.s.i. The orifice plate controls pressure by restricting volume and is limited to its design requirements for supplying _______
200 GPM
The stage for flashover is set when the heat of the fire liberates flammable gases from these synthetics. As the temperature of these gases increases, it reaches the flashover point, which may be as low as __________
700˚ F
One means of ventilating a floor or compartment of a high-rise building to eliminate a backdraft condition is to ___________ and horizontally ventilate the fire floor.
Break the windows
The RIC SCBA Kit consists of the following: Nylon bag with sling and carrying handles, 60 minute air cylinder, First stage pressure reducer with ____ feet of intermediate pressure hose, Second stage regulator, Facepiece, Pelican Flashlight with integrated holder, and ___ feet drop bag line)
10’
150’
What are the components of Pre-fire planning a high rise building ?
- physical condition
- study of past fires
- thorough knowledge of tools and using them effectively
One of the most important things to remember is to ______________________________________
Find someone from the building that is familiar with the fire control room