B2102 - RPV Pressure instrumentation Flashcards

1
Q

What does RPS do? at what pressure?

A

Scram @ 1064.7 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the narrow range setpoints?

A
  1. 1095 psig high pressure alarm
  2. < 7.4 delta T Rx sat, and
    recirc suction ——— downshift recirc pump
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the wide range setpoints?

A

1126 psig recirc pumps trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the safety pressure limit?

A

1325 psig at dome, to prevent 1375 psig at bottom

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the tech spec pressure limit?

A

1045 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the LO LO set logic?

A

Relief LO LO Reset
51D 1103 1033 926
51B 1113 1073 936
41D 1113 1113 946
41G 1113 1113 946
51A 1113 1113 946
51F 1113 1113 946

** Dad Burn Durn Green Apple Farts **

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When is wide range automatically selected?

A

< 865 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Where does RPV system instruments detect Rx pressure?

A

Condensing chamber

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the purpose of RPV pressure instrumentation?

A

Monitors pressure during normal ops, start up, shutdown, and post accident conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the narrow range pressure range?

What condensing pot does it use?

A

850 - 1150 psig

D004

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the wide range pressure range?

Where can the ranges be read from?

A

0-1200/1500 psig
0-1200 (P680)
0-1500 (P601 and RSDP)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly