B2102 - RPV Pressure instrumentation Flashcards
What does RPS do? at what pressure?
Scram @ 1064.7 psig
What are the narrow range setpoints?
- 1095 psig high pressure alarm
- < 7.4 delta T Rx sat, and
recirc suction ——— downshift recirc pump
What are the wide range setpoints?
1126 psig recirc pumps trip
What is the safety pressure limit?
1325 psig at dome, to prevent 1375 psig at bottom
What is the tech spec pressure limit?
1045 psig
What is the LO LO set logic?
Relief LO LO Reset
51D 1103 1033 926
51B 1113 1073 936
41D 1113 1113 946
41G 1113 1113 946
51A 1113 1113 946
51F 1113 1113 946
** Dad Burn Durn Green Apple Farts **
When is wide range automatically selected?
< 865 psig
Where does RPV system instruments detect Rx pressure?
Condensing chamber
What is the purpose of RPV pressure instrumentation?
Monitors pressure during normal ops, start up, shutdown, and post accident conditions
What is the narrow range pressure range?
What condensing pot does it use?
850 - 1150 psig
D004
What is the wide range pressure range?
Where can the ranges be read from?
0-1200/1500 psig
0-1200 (P680)
0-1500 (P601 and RSDP)