Sample containers shall be equipped with a pressure relief set to hold no less than.
8-10 psi
Sample container shall hold no more than … And no less than… %
25-80%
Optimal sample container volume is between…
60-80%
If the sample container is outside allowable volume is it required to fill out an MDN?
Yes
What does MDN stand for?
Measurement Deficiency Notification
For LACT and other commingled applications the sample container must be cleaned and inspected how often.
Once a year
How often does a batch application need to be drained and cleaned?
After each use
If seals have been broken or you see evidence of tampering what should you do.
Contact your supervisor as soon as practical. Also record tampering in the “Remarks” section of the Measurement Ticket.
If the sampler contains less than 25% what should you do.
Pump the contents into a sample container and notify supervisor. Also write an MDN to have the sampler repaired.
How long do you mix the contents of the sampler?
5 minutes or enough to cycle contents 3 times.
How long do you wait between gathering centrifuge samples?
2 minutes
Where do you record security seal numbers that have been removed?
In the Measurement Log Book (MLB) or source document.