ATA 80 GE Flashcards

1
Q

Which component supply ground to hold start selector in start position
a AIMS
b ELMS
c EEC

A

A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How EEC gets the starter valve position

a Use valve RVDT

b Use valve position switch

c Use downstream pressure sensor

A

C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When does EEC close starter air valve
a N2 reach 50%
b N2 reach 56%
c N2 reach 64%

A

C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How many autostart tries can carry out by EEC
a 2
b 3
c 4

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

EEC monitors starter air valve position by signal from (B1)
a. Starter air pressure sensor
b. Valve position transducer
c. Feed back LVDT

A

A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

You manually open the starter air valve by (B1)

a. A manual drive access on the fan case

b. A separate extension thru the valve manual drive access

c. A handle that integrated to thrust reverser half

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Do you need to add oil to the starter periodically after having it filled after installation? (B1)

a. Yes. At every A-chk the starter must be service

b. No. It is automatically kept full by engine oil system

c. Yes. Use the sight glass to determine if it is necessary to add oil

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Can you open the starter air valve when N2 is more than maximum starter engagement limit? (B1)

a. No. You have to wait until N2 less than 50% before re-engagement

b. No. Precaution must be taken not to damage the starter

c. No. SAV logic inside the EEC does not open the starter air valve

A

C*

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which of the following parameters EEC does not use as an input to find starting fault? (B1)
a. N2
b. Oil pressure
c. EGT

A

B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

During a manual start, when you put Fuel Control switch to RUN with N2 less than 18% (B1)

a. You will receive an advisory message ENG AUTOSTART to show that the start procedure is incorrect

b. You will receive an advisory message ENG MANUALSTART to show that the start procedure is incorrect

c. You will receive a status message ENG AUTOSTART to show that the start procedure is incorrect

A

A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly