1
Q
What are the 5 modes of operation for the electrical system?
1
2
3
4
5
A
  1. Normal-2gen, NR>88%
  2. Stby-1gen
  3. Emergency- 0gen//batteries only
  4. Stby Gen- APU Gen (30min max)
  5. External power-(AC or DC)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

In standby operations mode what system will not work?

A

Main and Tail Rotor de-ice will not work

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

In Emergency Operations how long should the batteries supply power?

A

6-7min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How much power do the Generators produce?

A

40KVA (Voltage regulators maintain output at 200 +/- 4 VAC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where on the aircraft are the rectifiers physically located?

A

forward fuselage behind co-pilot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When the while lights will not functions what is the first item to check?

A

Check if left cabin door is open (microswitch)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What does the EQUIP TEST switch do?

A

Connect the Stby Gen to the T/R Bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How long can the APU in Stby Gen mode be run?

A

30min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What do the T/R’s convert?

A

208VAC to 27VDC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the AC voltage output of the generators and how is it regulated?

A

204 +/- 4 VAC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly