AQC VIII: Electrical Flashcards
What are the 5 modes of operation for the electrical system? 1 2 3 4 5
- Normal-2gen, NR>88%
- Stby-1gen
- Emergency- 0gen//batteries only
- Stby Gen- APU Gen (30min max)
- External power-(AC or DC)
In standby operations mode what system will not work?
Main and Tail Rotor de-ice will not work
In Emergency Operations how long should the batteries supply power?
6-7min
How much power do the Generators produce?
40KVA (Voltage regulators maintain output at 200 +/- 4 VAC)
Where on the aircraft are the rectifiers physically located?
forward fuselage behind co-pilot
When the while lights will not functions what is the first item to check?
Check if left cabin door is open (microswitch)
What does the EQUIP TEST switch do?
Connect the Stby Gen to the T/R Bus
How long can the APU in Stby Gen mode be run?
30min
What do the T/R’s convert?
208VAC to 27VDC
What is the AC voltage output of the generators and how is it regulated?
204 +/- 4 VAC