What does the illumination APU MASTER SW FAULT indicate?
- Automatic APU shutdown has occurred.
What is the significance of the APU AVAIL light illuminating?
- APU is running above 99.5 % or 2 seconds after N speed reaching 95%. In practical terms it is ready to accept and support ELEC and/or AIR load.
What condition in the APU system would cause an external horn to sound on the ground?
- APU fire.
With the APU green AVAIL light ON and the EXT PWR green AVAIL light on, which system is powering the aircraft?
2 Avails = APU powering the aircraft.
If possible, how would the APU be used if it has already started the cooldown cycle?
- Pressing the APU MASTER SW pushbutton.
When running the securing checklist why is it important to wait 2 minutes after the APU avail light goes out before switching off the batteries?
- Switching the batteries off before the APU flap is closed may cause smoke in the cabin during the next flight.
If one generator fails, what is the maximum altitude that you can start the APU?
- FL 410
If your aircraft is in an emergency electrical configuration, what is the maximum altitude to start an APU?