APU Flashcards
What is the primary function of the APU?
Starting engines
What is the APU fuel burn?
150 lbs. per hour
Is there an external APU shutoff?
Yes, External Power Control Panel below the right engine
APU gets fuel from where?
Right collector tank
How is fuel fed to the APU?
Right fuel pump until RT engine is running, then ejector pump supplies the fuel
You are being de-iced prior to departure. What must you consider regarding the APU?
De-icing with the APU running is prohibited
Prior to starting the APU you should ensure what minimum battery voltage?
20.5 volts ***(Flexjet CFM)
What does the APU provide us with?
(4)
Bleed air for air conditioning, pressurization, engine start and DC Power
How many fire bottles are dedicated to the APU?
1-the number two bottle
Is the APU fire protection system automated while on the ground?
Yes, it will shutdown and discharge the number two bottle
Can the APU be operated with the APU generator inoperative?
Yes per the MEL
What happens with the batteries when starting the APU?
The Right battery PBA shows off and is powering only the APU starter.
The Left battery is powering the rest of the aircraft including the start logic for the APU.
What APU is installed?
Honeywell 36-150BD