If AC BUS 1 fails, will the AC ESS BUS remain powered?
(ELEC Panel)
Yes
If AC BUS 1 fails, which bus supplies the AC ESS BUS?
(ELEC Panel)
AC BUS 2
What is indicated by a FAULT light in the GEN pb?
(ELEC panel)
The associated generator control unit (GCU) trips
OR
The line contactor opens (except if GEN pb is selected OFF)
What does a BAT OFF light represent?
(3 things)
(ELEC Panel)
Battery charger limiter is not operating
OFF light illuminates if the DC BATT BUS is powered
Hot buses remain powered
What does the greeen EXT PWR AVAIL light indicate?
(ELEC Panel)
EXT PWR is connected and good
What does the blue EXT PWR ON light indicate?
(ELEC Panel)
EXT PWR is connected (supplying power) to the ELEC system.
What does the battery charger limiter automatically control? (when the BAT 1&2 are selected on)
ELEC Panel
Connection and the disconnection of the corresponding battery to the DC BAT BUS (by closing and opening of the battery line contactor)
What does a BAT FAULT light represent?
(ELEC Panel)
Comes on amber light with an ECAM caution message. (when the charging current for the corresponding battery is outside limits.)
What does the AC ESS FEED FAULT light represent?
(ELEC Panel)
AC ESS BUS is not powered
What does a FAULT light in IDG 2 pb represent?
(ELEC Panel)
High oil temp/ Low oil pressure
During One Engine Taxi:
1) which GEN is powering AC BUS 1?
2) AC BUS 2?
1) GEN 1
2) APU (bus tie)
What does the smoke light in GEN 1 LINE pb indicate?
(EMER ELEC PWR Panel)
Smoke is detected in the avionics ventilation duct
What occurs when the GEN 1 LINE pb is selected OFF?
(3 things)
(EMER ELEC PWR Panel)
GEN 1 line contact opens
AC BUS 1 channel supplied from GEN 2 through BUS tie contacts
Separate circuit is energized from GEN 1 to supply power to one fuel pump in each main tank.
What is indicated by a RAT & EMER GEN FAULT light?
(EMER ELC PWR Panel)
EMER GEN is not supplying power when AC BUS 1 & AC BUS 2 are not powered.
With the RAT MAN ON sw in AUTO, what will cause the RAT to deploy?
(EMER ELEC PWR Panel)
AC BUS 1&2 not supplied, AC Speed greater than 100 kts