Air Conditioning, Pressurization and Pneumatics/Bleed Air Systems Flashcards
The pack INOP light illuminates and a L or R PACK TEMP advisory displays for all pack control system faults and overheats. If the INOP light illuminates and remains illuminated after selecting STBY‐N for the affected pack, what is the fault?
A pack overheat. After the pack has cooled, an attempt to restore pack operation may be made by pushing the PACK RESET switch.
The pack INOP light illuminates and a L or R PACK TEMP advisory displays for all pack control system faults and overheats. In addition, the PACK OFF light illuminates and a L or R PACK OFF advisory displays when:
An internal pack overheat is detected. The pack valve closes and the pack is shut down automatically.
Pushing the Cargo Fire DEPR will cause:
One air conditioning pack to go to low flow and the other pack to shutdown. All conditioned air is shutoff to the cabin and diverted to the cockpit to supply fresh air to the crew.
What does a PACK OFF light and associated EICAS message indicate?
Respective pack valve closed
What can cause a Compartment Temperature INOP light to illuminate?
Zone air overheat or fault in zone temperature controller
What does the Cabin Altitude AUTO INOP light indicate?
Both Auto 1 and 2 are inoperative or manual mode selected
(757) Which condition automatically opens the overboard exhaust valve?
The recirculation fan fails
(RR) With the High Altitude Landing switch ON, what cabin altitude annunciates the CABIN ALTITUDE light and EICAS message?
14,650 ft
During automatic temperature control, which temperature zone controls the output temperature of the air conditioning packs?
The zone requiring the coolest air
What altitude setting is selected on the Landing Altitude Indicator during cockpit preparation?
Landing altitude in feet
What occurs if the Cabin Altitude Mode selector is set to AUTO 1 and it fails?
Control is automatically switched to Auto 2 controller
What could cause Compartment Temperature INOP lights to illuminate?
Trim air switch is OFF
What happens when an automatic control system fault or a pack outlet overheat is
detected?
The pack continues to operate in an uncontrolled,
degraded condition, requiring crew action
What does the Pack Reset switch do when pushed?
Resets an overheated pack if the pack has cooled to a
temperature below the overheat level
When a Pack Control selector is positioned to STBY N, what is the outlet
temperature of the pack in flight?
A constant, moderate temperature (40°F inflight)