6-3 FOOD SERVICE MATERIALS AND EQUIPMENT Flashcards
LEAD EQUIPMENT USED IN CONTACT WITH FOOD SHALL BE LEAD FREE; SOLDER LEAD MUST BE LESS THAN:
0.2
COPPER MAY NOT BE USED IN CONTACT WITH A FOOD THAT HAS:
A PH BELOW 6
WHAT TYPE OF PALLETS MAY BE USED FOR FOOD STORAGE
NSF INTERNATIONAL LISTED PLASTIC OR WOOD
FOOD TEMPERATURE MEASURING DEVICES MAY NOT SENSORS OR STEMS CONSTRUCTED OF _____ GLASS, EXCEPT IF IT IS ENCASED IN ________ COATING
- GLASS
- SHATTERPROOF
FOOD TEMPERATURE MEASURING DEVICES THAT ARE SCALED ONLY IN CELSIUS OR DUALLY SCALED IN C OR F SHALL BE ACCURATE TO _____ IN THE INTENDED RANGE OF USE.
-+1 C
FOOD TEMPERATURE MEASURING DEVICES THAT ARE SCALED ONLY FAHRENHEIT SHALL BE ACCURATE TO ____ IN THE INTENDED RANGE OF USE
-+2 F
TEMPERATURE MEASURING DEVICES, AMBIENT AIR AND WATER
DEVICES SCALED IN C OR DUALLY SCALED IN C AND F SHALL BE ACCURATE TO THE ____
-+1.5 C
TEMPERATURE MEASURING DEVICES, AMBIENT AIR AND WATER
DEVICES SCALED ONLY IN F SHALL BE ACCURATE TO THE ____
-+3
PRESSURE MEASURING DEVICES
SHALL HAVE INCREMENTS OF ______ OR SMALLER AND SHALL BE ACCURATE TO _________
- 7 KILOPASCALS (1 POUND PER SQ INCH)
- + `4 KILOPASCALS (-+2 POUNDS PER SQ INCH)
VENTILATION IS USED TO REMOVE:
-DUST, GREASE, HUMIDITY, HEAT, SMOKE, ODOR
FOOD AND WATER TEMPERATURE MEASURING DEVICES SHALL HAVE A NUMERICAL SCALE AND INCREMENTS NO GREATER THAN
2F OR 1 C
ALL FOOD EQUIPMENT AND UTENSILS USED IN A FOOD ESTABLISHMENT SHALL MEET WHAT STANDARDS OR CRITERIA
- NSF INTERNATIONAL
- UNDERWRITERS LABS
- USDA
- BAKING INDUSTRY SANITATION STANDARDS COMMITTEE (BISSC)
MANUAL WAREWASHING IS DONE IN WHAT TYPE OF SINK?
3 COMPARTMENT SINKS
WHAT ARE THE THREE COMPARTMENTS FOR IN THE MANUAL WASHING SINK?
- WASHING
- RINSING
- SANITIZING
FOOD SERVICE EQUIPMENT SHALL BE INSTALLED USING GUIDANCE PROVIDED IN
- NSF INTERNATIONAL INSTALLATION MANUAL
- USACHPPM
- FDA FOOD ESTABLISHMENT PLAN REVIEW GUIDE
COUNTER MOUNTED OR TABLE MOUNTED EQUIPMENT SHOULD BE ELEVATED ON LEGS THAT PROVIDE AT LEAST ____ CLEARANCE BETWEEN THE FLOOR AND EQUIPMENT
4 INCHES
FIXED FLOOR MOUNTED EQUIPMENT THAT IS NOT EASILY MOVABLE SHALL BE ELEVATED ON LEGS THAT PROVIDE AT LEAST ____ CLEARANCE BETWEEN THE EQUIPMENT AND FLOOR
6 INCHES
HOW OFTEN SHOULD ELECTRIC MOTORS, REFRIGERATION COMPRESSORS, CONTROLS, AND OTHER AREAS NOT NORMALLY ACCESSED BE CLEANED?
SEMI ANNUALLY