3.9 Refueling Operations Flashcards
3.9.1 Boron Concentration
Boron concentration of the Reactor Coolant System (RCS), the fuel
transfer canal, and the refueling cavity shall be maintained within the limit
specified in COLR.
APPLICABILITY: MODE 6. -------------------------------------------------------------------------------------------------- - NOTE - Applicable to the fuel transfer canal and the refueling cavity only when connected to the RCS. -------------------------------------------------------------------------------------------------- ACTIONS A. Boron concentration not within limit. A.1 Suspend positive reactivity additions. Immediately AND A.2 Initiate actions to restore boron concentration to within limits. Immediately
3.9.2 Unborated Water Source Flow Paths
One valve in each unborated water source flow path shall be secured in
the closed position.
APPLICABILITY: MODE 6.
ACTIONS - NOTE - Separate condition entry is allowed for each unborated water source flow path. -------------------------------- - NOTE - Required Action A.2 must be completed whenever Condition A is entered. -------------------------------- One or more unborated water source flow paths with no valve secured in the closed position. A.1 Initiate actions to secure one valve in the flow path in the closed position. Immediately AND A.2 Perform SR 3.9.1.1. 4 hours
3.9.3 Nuclear Instrumentation (Source Range)
Two source range neutron flux monitors shall be OPERABLE.
APPLICABILITY: MODE 6.
ACTIONS A. One required source range neutron flux monitor inoperable. A.1 Suspend positive reactivity additions. Immediately AND A.2 Suspend operations that would cause introduction into the Reactor Coolant System (RCS), coolant with boron concentration less than required to meet the boron concentration of LCO 3.9.1. Immediately B. Two required source range neutron flux monitors inoperable. B.1 Initiate action to restore one source range neutron flux monitor to OPERABLE status. Immediately AND B.2 Perform SR 3.9.1.1. (Boron Conc.) Once per 12 hours
3.9.4 Refueling Cavity Water Level
Refueling Cavity Water Level shall be maintained ≥ 23 ft above the top of
the reactor vessel flange.
APPLICABILITY: During movement of irradiated fuel assemblies within containment.
ACTIONS A. Refueling cavity water level not within limit. A.1 Suspend movement of irradiated fuel assemblies within containment. Immediately
3.9.5 Decay Time
The Reactor shall be subcritical for ≥ 48 hours.
APPLICABILITY: During movement of irradiated fuel in the reactor pressure vessel.
ACTIONS
A. Reactor subcritical < 48 hours.
A.1 Suspend all operations involving movement of irradiated fuel in the reactor pressure vessel.
Immediately