2.0 Safety Limits Flashcards
1
Q
2.1.1 Reactor Core Safety Limits
A
Shall not exceed combination of Thermal power/Highest RCS Tcold and Pressurizer Pressure per COLR
This shall prevent exceeding DNBR of ≥ 1.14 and maintain fuel centerline temperature < 5080°F, decreasing 58°F per 10,000 MWD/MTU of burnup.
APPLICABILITY: Modes 1 and 2
ACTIONS
Restore compliance and be in Mode 3 within 1 hour
2
Q
2.1.2 RCS Pressure Safety Limit
A
RCS Pressure shall be maintained ≤ 2733.5 psig.
APPLICABILITY: Modes 1, 2, 3, 4, and 5
ACTIONS
In Mode 1 and 2, restore compliance and be in Mode 3 within 1 hour
In Mode 3, 4, and 5, restore compliance within 5 minutes.