27.5 AV LIGHTING Flashcards

1
Q

27.5 AV LIGHTING

A

27.5 AV LIGHTING

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Difference between beam angle and field angle?

A

Beam Angle is the usable hot part of the light; field angle is the total throw of the light - even the part that is unusable and dim.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

To get the size of the pool of light that a Source 4 Leko makes; this multiplier decimal and multiply it by the throw distance.

A
90°	 -   (1.88)	
70°   -   (1.4)	
50°	 -   (.95)	
36°	 -   (.63)	
26°	 -   (.45
19°	 -   (.32)	
14°	-   (.26)	
10°	-    (.19)	
5°	-    (.12)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Number of 575watt Leko’s you can run off of a 20 Amp circuit?

A

3 safely (20 Amps is equivalent to 2400 watts) (2400 wats divided by 575 wats is 4.17 … So (3) is a nice safe number - you could do 4 if you had too (and if there was very little cable run)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In Ponce there are (4) dimmers that can be accessed in each of the ponces or in iterations of the ponce opened up. Each of these 4 dimmers can run (3) lights (in each space)

A

Ponce dimmers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly