240, Electrical Flashcards

1
Q

With the GALY & CAB pb in the AUTO position and only one engine generator operating:

A

Automatic Galley Bus shedding occurs for the main galley, in-seat power supply, and in-flight entertainment.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A FAULT light in the GALY & CAB pb appears when any generator load is above 100% of its rated output.

T/F?

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

All circuit breakers on the overhead panel are associated with systems which are powered:

A

While in the emergency electrical configuration.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Color coding is used to identify circuit breakers with different characteristics.

A

Green colored circuit breakers are monitored by the flight warning computers.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Activation of the RAT MAN ON pb will cause immediate deployment of the RAT except when no power is on the aircraft.
T/F?

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The electrical system consists of:

Two aircraft batteries.

Two engine driven IDG’s.

An emergency generator.

All of the above.

A

All of the above.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When external power is connected to the aircraft, a green AVAIL light indicates:

A

External power is connected with acceptable voltage and frequency.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

During non-normal conditions, the IDG may be disconnected for its engine and:

The IDG pushbutton should not be pressed for more than 3 seconds.

Once disconnected, the IDG cannot be reconnected in flight.

The IDG pushbutton should only be used when the engine is running or wind milling.

All of the above

A

All of the above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The RAT automatically deploys when:

A

Power is not available for AC Bus 1 and AC Bus 2 and airspeed greater than 100 knots.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

You can deploy the RAT and activate the emergency generator using the MAN ON pb.
T/F?

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The APU generator always takes priority over an engine driven generator and/or external power.
T/F?

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The APU driven generator:

A

Can be used as the sole source of electrical power on the ground.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When the APU generator is on and no other AC sources are available, the APU can power the entire electrical system on the ground.

T/F?

A

TRUE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The AVAIL light illuminated on the EXT PWR pb means:

A

Voltage and frequencies are acceptable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What does the OFF message under the APU GEN on the ELEC page indicate?

A

APU GEN pb has been selected OFF with the APU running.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What electric source has priority with the engines off, APU available and the EXT PWR pb switch is ON.

A

EXT PWR

17
Q

Disconnecting an IDG:

A

Renders the associated electrical generator inoperative

18
Q

To avoid damage to the IDG, what must not be pressed for more than 3 seconds?

A

IDG disconnect pbs

19
Q

The “RAT OUT” memo on the E/WD indicates:

A

The RAT has deployed