Function of RCB Chilled Water
Provide chilled water to the RCFCs under normal conditions and the RCS Vacuum Degassing System (cools compressor)
- 50% CAPACITY PUMPS & CHILLERS*
- (2 NORMALLY RUN)*
- HEAT IS REJECTED TO THE OL-ACW SYSTEM*
- 202.32 RCB Chilled Water*
- *
Location of pumps, chillers, expansion tank
RCB CHILLERS - 29’TGB
CHILLED WTR PUMPS - 10’ MAB
EXPANSION TANK - 60’MAB
- 202.32 RCB Chilled Water*
- *
Makeup source to RCB Chilled Water Expansion Tank
Automatic makeup from demin water
- 202.32 RCB Chilled Water*
- *
Behavior of RCB Chilled Water and CCW CIVs
RCFC CHILLED WATER CONTAINMENT ISOLATION VALVES
Normal Open/Close features. In Auto valves close on SI & LOOP.
RCFC CCW CONTAINMENT ISOLATION VALVES
Normal Open/Close features except that valves won’t open unless Chilled Water valves are closed. In Auto, CCW valves open on an SI, but remain closed on a LOOP.
B Train valves have power lockout function due to location in RCB vulnerable to being underwater post-accident
- 202.32 RCB Chilled Water*
- *
Power supplies
RCB Chiller 11A - 4.16 KV SWGR 1D1
RCB Chiller 11B - 4.16 KV SWGR 1D2
RCB Chiller 11C - 4.16 KV SWGR 1D2
RCB Chill Water Pump 11A - 480V LC-1J
RCB Chill Water Pump 11B - 480V LC-1K
RCB Chill Water Pump 11C - 480V LC-1L2
- 202.32 RCB Chilled Water*
- *
Normal Pump Configuration
One pump per chiller is normal.
Balanced for 2 pump operation with 2 trains of RCFCs in service
A pump in AUTO will start if running pump trips.
- Too many RCFCs lined up for pumps running could cause runout*
- Too few chillers could lift relief*