2. Electrical Flashcards

1
Q

How many Amps are the starter generators?

A

200A

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How is the battery connected to the main DC buses?

A

Connected to the left dc bus (both when bus tie is in normal position)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What does the DC Voltmeter indicate?

A

Voltage present on left DC bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What does the DC loadmeter indicate?

A

Displays load on either left generator, right generator or battery.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the function of the reverse current circuit breaker (RCCB)? Where is it located?

A

Disconnecting the main battery from the left DC bus if the sustained charging current ever exceeds 450 amps.
Located in the main cabin roof.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How are the inverters powered?

A

NO 1 inverter receives DC power from the left DC bus, and NO 2 inverter receives power from the right DC bus.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is powered by the 115V AC BUS? (FAH)

A
  1. Fuel Quantity Gauges
  2. Attitude Indicator
  3. HSI
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is powered by the 26V AC BUS? (TOF)

A
  1. Torque Gauges
  2. Oil Pressure Gauges
  3. Fuel Flow Gauges
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How are the generators brought online?

A

By pushing the GENERATOR switch from the OFF position momentarily forward to the RESET position

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What should be done if a significant electrical load is anticipated when the generators will be brought online?

A

Increase Ng to Idle Ng +15%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

For any abnormality, what is the maximum reset attempts for either generator?

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What are the dry motoring/ abnormal operation starter limitations?

A

25 seconds ON, 60 seconds OFF
25 seconds ON, 60 seconds OFF
25 seconds ON, 30 minutes OFF
(These limits do not apply to normal starts)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How is the battery charged under normal conditions?

A

From either generator.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where is the main battery located?

A

Beneath the aft baggage compartment floor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

For ground ops above 7deg C, the Gen loadmeter reading should be?

A

0.8 or less

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When used, the emergency lights receive power from?

A

Internal batteries

17
Q

Where are forward and aft bag area lights powered from?

A

The hot battery bus

18
Q

How many volts is the electrical system?

A

28V DC

19
Q

What are the primary and secondary sources of DC power?

A

Primary- 2 starter generators

Secondary- 24V DC battery

20
Q

How is the scale of the loadmeter graduated?

A

Positive and negative units of 0.1, from -1.0 to +1.0.
BAT position, 0.1. equals 10 amps.
L GEN or R GEN position, 0.1 equals 20 amps.