17---Friday---Gas Levels of Machinery From Coal Mines safety and Health regulations 2001---updated 1st Feb 2016 Flashcards

1
Q

What are the Trip and alarm levels for

  • ERZ NERZ Boundry
  • NERZ NERZ Boundary

as detailed in section 242 of the regulations?

A
  • Regulations
    • ERZ/NERZ
  • Alarm 0.25%

Trip 0.5%

(s242)

  • NERZ/NERZ
  • Alarm 0.25%

Trip 0.5%

(s242)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the Trip and alarm levels for an Auxillary fan?

A

Regulations

Auxiliary fan (s231)

No alarm in Regulations

Trip 2%

Cooks SOP

Alarm 1%

Trip 1.25%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the Trip and alarm levels for an Shearer?

A

Regulations

Shearer (s234 )

Alarm 1%

Shearer drum / Heads trip 1.25%

General body 2%

Cooks SOP

Alarm 1%

Shearer drum / Heads Trip 1.25%

General body 2%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the Trip and alarm levels for a Miner?

A

Miner (s233)

Regulations

Alarm 1%

Heads Trip 2%

General body 2%

Cooks SOP

Alarm 1%

Heads Trip 2%

General body 2%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the Trip and alarm levels for a Bolter

A

Bolter (s235)

Regulations

Alarm 1%

General body 2%

Cooks SOP

Alarm 1%

General body 2%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the Trip and alarm levels for MG

A

MG (s244)

Regulations

NO Alarm

General body 2%

Cooks SOP

Alarm 1%

Trip 2%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the Trip and alarm levels for TG

A

TG, (s244)

Regulations

NO Alarm

General body 2%

Cooks SOP

Alarm 1%

General body 2%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the Trip and alarm levels for LHDs

A

LHDs (s246)

Regulations

Alarm 1%

General body 1.25%

Cooks SOP

Alarm 1%

General body 1.25%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are the Trip and alarm levels for the main fan

A

Main Fan (s232)

Requires at least 1 CH4 detector

Alarms at set level as stated in sites PHMP, L-1%, H-1.25%)

Fan does not Trip

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the Trip and alarm levels for - 4 ways (s243)

A

All Trolex sensors-Gas Sensor Range Settings

CH4–0>5.00%

A1-1%

A2-1.25%

CO– 0>50.00ppm

A1-6ppm

T2-8ppm

CO2– 0>2.00%

A1-1%

A2-1.25%

O2– 0>25.00%

A1-20.5%

A2-19%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What are the Trip and alarm levels for CO sensors?

A

CO levels are not prescribed by regs and are subject to change with the ventilation (set by L/make)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What should a CO sensor do if it alarms on a belt?

A

CO levels are not prescribed by regs and are subject to change with the ventilation (set by L/make)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What does a CH4 sensor also do what with repect to a belt?

A

CH4 sensors have a dual purpose of tripping the belt at 1% Not at cook Though!