0POP03-ZG-0006 Plant S/D 100% to MODE 3 Flashcards
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
What is runout speed for the condensate pump?
11,000 gpm
Condensate flow is ≈ 7,500 gpm at 40% Rx Power
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
When must 2 CARS pumps be in operation?
Rx Power < 30%
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
When are expanded ranges NOT allowed to be used to meet values/ranges in this procedure?
Meeting Tech Specs
> 98% Rx Power
< 10% Rx Power
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
Why does placing excess letdown in service make U1118 inaccurate?
Bypasses Instrumentation
U1118 becomes inaccurate in the non-conservative direction.
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
When should Rx Engineering supply an axial flux control strategy?
RTP of < 85% for > 2 weeks anticipated
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
What should RCS boron concentration be limited to?
- < 1 hr after S/D:*
- *2500 ppm**
- > 1 hr after S/D:*
- *3500 ppm**
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
What is differential boron concentration limit between the RCS and PZR?
50 ppm
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
When below the POAH, how should the operator stop an uncontrolled cooldown?
Isolating secondary heat loads
Do NOT dilute or pull rods to stop the cooldown.
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
When should Polyacrylic Acid (PAA) dispersant injection be isolated?
Before Reducing Rx Power < 30%
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
When must rods be placed in manual?
Turbine load lowers to ≈ 208 MWe
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
How does the operator fully shut 1(2)-FW-MOV-0108 (FW Heater 11A/B bypass isolation MOV)?
Hold the jog switch in the closed direction until the torque limit switch turns off the motor.
Lights will show valve is shut when it is still 5% open.
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
What is the Rx power limit for feeding the SGs through the main feed nozzle?
4%
Prevents thermal stratification when feedwater flows are less than 125,000 lbm/hr
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
When is Tref and Program Tavg equal?
100% RTP
Program Tavg is linear when going from 0% to 100% and Tref is not.
- Note:*
- Rod motion can occur in as little as 0.3 ˚F temperature mismatch.*
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
When must Chemistry perform an isotopic analysis of the RCS for Iodine to satisfy Technical Specifications?
Change in RTP of > 15% in any 1 hr period.
- 0POP03-ZG-0006 Plant S/D 100% to MODE 3*
- *
What must be performed if ≥ 2 rods do not insert on a Rx Trip?
Emergency Borate