0POP03-ZG-0005 Plant S/U to 100% Flashcards

1
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

If the fuel is conditioned, how quickly can the operators raise power from 0% -100%?

A
  • Should:*
  • *≤ 10%/hr**
  • Shall:*
  • *≤ 12%/hr**

Conditioned fuel has ≥ 72 hrs in any 7 day period at > 95% RTP.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

What must the margin to OT∆T be maintained at?

A

≥ 5% Margin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

How many loop feedwater temperatures are required for calorimetric uncertainty?

A

3 Loops

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

How long should DA pressure be maintained > 35 psig prior to placing PV-7174/PV-7174A MS Supply Valves in the MOD position?

A

30 mins

Low pressure causes the controller to saturate causing PV‑7174 and PV‑7174A to open. A potentially severe hydraulic transient could occur.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

What are the open permissives for the FWIVs?

A

SGNR Level > 5%

SG Pressure > 685 psig

  • FWIVs fail closed on loss of hydraulics/power. (Will not close on loss of N2 pressure)
    • Hydraulic open / N2 closed
  • FW Isolation Energizes Train A/B solenoids, which secure the hydraulic pumps and dump hydraulic fluid (Manual switches [2 / SG] located on CP006)
  • Open permissives being met allows de-energizing Train A/B solenoids.

Note:
Same concept for FWIBs and Preheater Bypass Valves (PBVs) except solenoids de-energize to dump hydraulics and energize to allow opening.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

What must be done if both fans on the Isophase are lost?

A

Reduce Power to 50%

Lower Isophase Current to 18,500 Amps
Lower load at 5%/min
Generator Current on CP007

Normal current rating is 36,600 Amps

Note:
Isophase trouble on CP010.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

When should Feedwater be transferred from the LPFRVs to the MFRVs?

A

Prior to exceeding 75% on the LPFRVs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

At what power levels are the Low Power FRVs and Main FRVs used?

A
  • Low Power FRVs:*
  • *< 15%**
  • Fail closed on Loss of Air/Power*
  • Main FRVs:*
  • *≥ 15%**
  • Fail closed on Loss of Air ONLY*
  • Controlled from CP006
    • *

Note:
2 safety related solenoids for FW Isolation signal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

Describe how U1118 measures feedwater flow if LEFM system is lost?

A

Switches to Corrected Venturi Input
AND
Starts 72 hr timer

  • *Switches to Venturi Input when 72 hr timer expires**
  • *OR**
  • *> 10% drop in Rx power**
  • Limit Power to ≤ 99.6 RTP (3838 MWt)*

Correction Factors and Power level are captured when LEFM lost for Corrected Venturi Input.

Note:
Time Remaining changes from Cyan to Red when 6 hrs are remaining on clock.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

What should gland steam pressure be maintained less than?

A

< 140 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

If the fuel is unconditioned, how quickly can the operators raise power from 0% -100%?

A

0% - 50%:
Should: ≤ 10%/hr
Shall: ≤ 12%/hr

  • 50% - 100%:*
  • *≤ 3%/hr**

Hold Points:

  • 75% - 78%: 3 hrs
  • 95% - 98%: 10 hrs - previous hold points

Note:
To count as hold, must hold power ± 1% for ≥ 3 hrs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

When should a second condensate and FW booster pump be placed in service?

A

Prior to exceeding 30% power

Can wait up to 40% power but that will result in a chemistry action level.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

How is the preferred PZR pressure channel determined?

A

Select LOWEST PZR Pressure Channel

Obtains the highest OT∆T setpoint margin for the remaining loops.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

When Rx Power is > 50% and the power ascension rate is > 1%/hr, what should control rod withdrawal rate be limited to?

A

3 steps/hr

May exceed limit to limit AFD but cannot exceed 6 steps/hr

  • 50% - 75%: AFD ± 5% of target value
  • 75% - 100%: AFD ± 3% of target value
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

What are the restrictions for raising a SGFPT’s speed > 5400 RPM?

A
  • 5400 - 5500 RPM:*
  • *May be operated in this range indefinitely**

Each SGFPT’s flowrate > 8250 gpm

  • 5500 - 5600 RPM:*
  • *Operated in this range ≤ 1 hr**

Each SGFPT’s flowrate > 11000 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

What will auto open the exhaust hood spray valves?

A

Crossover Steam Pressure < 15%
AND
Turbine Speed > 600 RPM

  • Maintains spray pressure 116 psig (40 gpm)
  • Alarm set at 175 ˚F

Note:
Controlled on CP007

17
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

At what point in the Plant startup can the main generator be synced to the grid?

A

Rx Power ≥ 12%
AND
Steam Dump Dump Demand ≥ 13%

18
Q
  • 0POP03-ZG-0005 Plant S/U to 100%*
    • *

At what point during plant startup do we roll the main turbine?

A

Steam Dump Demand > 3%

Rx Power Stable or Rising

Establishes sufficient steam flow to allow rolling the turbine without primary/secondary plant perturbations.