Yoke Venting Flashcards

1
Q

Number of stories the upper vertical section of a stack needs passed through in order to require an offset relief event is

A

More than two stories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How many fixtures are permitted to be discharged into an offset relief vent or yoke vent

A

2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When a fixture is connected to a yoke vent or offset relief vent the minimum size of the pipe acting as a wet vent is

A

1 1/2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the maximum fixture unit load on individual fixtures that may be connecting to an offset relief vent or yoke vent?

A

1 1/2 fixture units

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Connecting more than one fixture to an offset relief, and the piping arrangement must be in the form of

A

A dual vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The maximum fixture load that made discharge into an offset relief vent or yoke vent is

A

Three fixture units

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Yoke vents are required when

A

The stack receives discharge from more than 11 stories

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When yolk vents are required, they are located…

A

Every five stories or part there of counted from the top down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The Yoke vent is sized to

A

One size smaller than the smallest pipe to which it is connected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

The yolk vent is connected to the vent stack

A

1000 mm above finished floor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The lower end of a yoke vent is connected to the soil or…

A

Above the highest connected fixture to the lower section of the soil or waist stack, and at the same elevation of the highest connected fixture to lower section of the soil or waist stack

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Or each story of the soil or waist is interconnected to the vent by means of vent pipe equalize to the branch or fixture drain or 2 inch in size; a Yoke vent is not required

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Soil stack to receive discharge from 18 stores with a total load of 205 fixture; how many yoke vents are required and what would be the size vent. The length of the vent stack is 50 m.

A

3 @ 2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly