Offset Relief Vents Flashcards
An offset relief vent is not required when the horizontal offset in the stack is
1500 mm or less
The recommended connection height of an offset relief vent to the vent stack is
1000 mm above finished floor
In An offset relief vent installation, where is the upstream relief fan connected to the stack
To the upper vertical section of the stack immediately above the offset
In an offset relief vent installation, where is the downstream, relief and connected to the stack
Any of the above
The size of an offset relief fence, serving a 6 inch soil stack would be
2 inches
The number of stories, the upper vertical section of a stack needs pass through in order to require an offset relief vent is
More than two stories
Horizontal offset in a 4 inch foil stack has is 2000 mm in length, the upper vertical section of the stack is five stories, high and receives a discharge of 145 FUs. Does this offset require an offset and if so what would be the minimum size
Yes, 1 1/2”
How many fixtures are permitted to be discharged into an offset relief vent?
2