Yirumba Flashcards
Yirumba Survey classes
2B: Non-passenger vessel (up to 12 passengers); Offshore operations (within 200 nautical miles from the baseline of the Australian mainland, Tasmania, a recognized island but within the exclusive economic zone)
2C: Non-passenger vessel (up to 12 passengers); Restricted offshore operations (within 30 nautical miles from the baseline of the Australian mainland, Tasmania, a recognized island; within 50 nautical miles of the baseline of Queensland, within the Great Barrier Reef Region or the Torres Strait Zone; whilst remaining within the exclusive economic zone)
3512 Jacket water flow
Bottom through the cooler with (bypass to after cooler) then to the top
Emergency electrical installation and equipment
Self contained source of electrical power, either a dedicated battery of diesel generator, to provide emergency power to all key systems for 3 hours (see NSCV Subsection C5B)
Emergency lighting
a) service alleys, accommodation alleyways, stairways, exits and personnel lift cars;
b) the machinery spaces and main generating stations, including their control positions;
c) control stations and all machinery control rooms;
d) the stowage positions for fire-fighting equipment;
e) the steering gear;
f) pumps for fixed fire extinguishing systems, emergency fire pumps and any bilge pump
relying on the emergency power source as its alternative power supply;
g) the starting positions for the motors of the pumps specified in clause 4.7(f);
h) public spaces, evacuation routes, exits and mustering areas;
i) lifeboat stations on deck;
j) stowage positions of life rafts for which launching devices are not provided;
k) life rafts and their launching devices during mustering and launching; and
l) the area of water into which life rafts are launched, for the period of time required for
launching to be completed.
Yirumba Fire pump and hose capacity
Fire hose
Single 12mm
Minimum throw of inclined water jet; 11m
Hydrant pressure KPa; 150
minimum fire hose nozzle flow rate m3/hour; 6.5
Minimum pump capacity per hose m3/hour; 7.0
Remote stops
Bilge pumps
2 x 11.0 kiloliters/hour capacity