XTRAP TRACTION Flashcards
How do the cab doors lock?
Slam lock when closed
What key is used to access the cab?
V29P
How many PIDS per car?
2
1 at each end
What end of the T car is the panto located?
No. 2 end
How can you identify which end is which when in the T car?
Air Conditioner Status Lights
Located on A side wall next to door 2
What equipment is located on the roof of the M cars?
HVACs
Resistor Grids
What equipment is located on the roof of the T cars?
Pantographs
HVACs
Lightning Arrestor
2 x High Speed Circuit Breaker (HSCB)
What 5 cocks are located in the Auxiliary Pneumatic Panel?
Horizontal:
Whistle
Uncoupling
Trip Cock Reset
Vertical:
Trip Cock Active
Auxiliary Pneumatic Panel
Where is the Auxillary Pneumatic Panel located?
B side on M cars
Near cab door and 8 wheel
Where are Brake Applied Indicator Lights found?
Each corner of all cars
What do the lights on the Brake Applied Indicators mean?
Red - EP brakes applied
Green - EP brakes released
What Isolating Cocks are on the Coupler?
Main Reservoir
Brake Pipe
Electrical Isolating Switch (on coupler)
Where is the Transition Coupler located?
No. 1 end, A side on M car
What cars have Disc brakes?
M cars only, 1 per Axel
(1, 3, 5, 7)
What cars have Tread brakes?
All cars, 1 per wheel
What cars/wheels have Spring Park Brakes?
M cars only
Wheels 1,3,7
What cars have Traction Motors?
M cars - 1 per Axel
What wheels on M cars have Wheel Slide Prevention Units?
2, 4, 6, 8
What is this on A side of the M/T car?
Electrical Box (E Box)
What container is located on the M car, what does it contain?
Traction Container
Contains:
Traction Inverter
Traction Control Unit
What voltage is fed into the Traction Inverter and what does it invert it into?
1500VDC
Inverted to 3 Phase Variable AC
What is on the outside of the Traction Container?
Traction Cooling Fan (B side)
Main Switch (A side)
What does the Line Inductor do?
Cleans the power
What does the TCU do?
Uses data on state of traction equipment, commands, speed and weight to determine how much power to send to the Traction motors
What does the Brake Rack contain and where is it located?
Located on B side of T and M cars
Contains:
Brake Module
Bogie 1 & 2 IC
Auxiliary Reservoir
Aux Res IC
Relay Valves
Drain Vale
What makes up the Pneumatic Supply System?
2 x Air Compressors
Main Reservoir
Compressor Governor IC
Compressor Governor
Air Dryer
What side of the T car has access to the Battery Box?
A side
What is the speed threshold for the DDU CCTV?
3km/h
If train has altered running, what must the driver do?
- Disable automatic announcements
- Select SERVICE CHANGE special message on DDU
- Make a PA and announce altered stopping conditions
What is the Full Cab Unattended Procedure?
- PA if necessary
- Ensure emergency brakes are applied
- Reverser to neutral, marker lights to white
- Take keys and portable Radio
- Lock cab door
What is the procedure for a Modified Cab Unattended Procedure?
- Ensure emergency brake applied
- Reverser to Neutral, marker lights to white
- Take keys
- Turn DTRS volume up
- Cab door does not need to be locked
How long after stabling does the marker lights and emergency saloon lighting turn off?
15 minutes
At what pressure does the second air compressor kick in for the main Reservoir?
650KPA
How long do doors 1,2,5,6 stay open once the controller key is removed?
10 minutes
At what pressure will the main res cause the safety loop to open
530KPA
What is the Main Reservoir Pressure when operating normally?
750 - 900KPA
At what pressure does the Main Reservoir Safety Valve open?
980KPA
What is the Brake Pipe pressure in normal operation?
0KPA
What is Brake Pipe Pressure in a Rescue Operation?
550KPA
At what pressure does the Brake Pipe open the safety loop?
300KPA
What is holding brake pressure?
120KPA
What pressure is Full Service Brakes?
190KPA
What pressure is Emergency Brakes?
210KPA
What is in the Auxiliary Pneumatic Panel?
Whistle
Uncouple
Trip Cock Active
Trip Cock Reset
Auxiliary Pneumatic Panel IC
What components make up the Compressed Air System? (9)
2x Air Compressors
Compressor Governor
Compressor Governor IC
Air Dryer
Main Reservoir
2x Auxiliary Reservoir
Main Reservoir Pipe
Brake Pipe
Auxiliary Pneumatic Panel
What are the positions of the EMY Mode Switch (EMS)?
- On-line Holding Brake Inhibit
- Normal
- Rescue
- Rescuing
- Rescuing in Propulsion
What does Permanent Low Voltage supply? (110vDC)
Panto Electric Motor
Cab Fluoro Light
Step Light
What does Prepared Low Voltage & Cab Operative supply? (8)
Panto Operation
Status & Fault Light Indicators
Traction Control
Brake Control
Safety Loop
Comms
EMY Saloon Lighting
Normal Saloon Lighting
What is supplied when in Prepared Low Voltage? (5)
Train remains prepared
Pantos raised
Settings of last cab memorised
Markers, door & saloon lights retain setting
Panto Up & Down latch buttons
What components make up the High Voltage System? (7)
Pantos
Lightning Arrestor
2x HSCB
Line Inductor
Traction Inverter
Resistor Grid
Auxiliary Inverter (SIV)
What are the components of the Low Voltage System? (6)
Auxiliary Inverter (SIVs)
400/220v AC System
110vDC System
HVACs
Air Compressors
Battery Charger
Traction Cooling Fans
What are the Safety Loop Bypass Switches? (4)
Safety Loop Bypass (sealed)
Auto Vigilance Bypass (sealed)
Tacho Bypass (sealed)
Door Loop Bypass
When over 0.5km, what does the Tacho inhibit? (4)
Door Release
Uncouple
Safety Loop Reset
Trip Reset
What are the positions of the Tacho Bypass Switch?
Normal & Bypass
What are the switch positions for Auto Vigilance Bypass?
Normal and Bypass
When Auto Vigilance has been Bypassed, what is isolated?
Trip, Hand & Foot Pilot
What are the positions of the Safety Loop Bypass Switch?
Normal, Test, Bypass
If the Safety Loop has been Bypassed, how can the Emergency Brake be applied?
Releasing the Bypass Switch will apply the Emergency Brake
What can cause the Safety Loop to open? (11)
- Main Res pressure below 580KPA
- Brake pressure below 300KPA
- Trip Activated/Raised
- VICERS
- Hand/Foot Pilot not set
- Loss of 110vDC
- Master Controller in EMY
- ESB
- 2 or more keys inserted
- Emergency Auto Vigilance button not pressed within 40 sec when operated
- 23Q1 or 23Q2 short circuit
What does the SIVs power?
Battery Charger
2x Air Compressors
2x Traction Cooling Fans
HVACs
400/220vAC System
110vDC System
If 1 SIV is lost, what is powered by the remaining SIV? (5)
No. 1 HVACs
No. 1 Air Compressor
Full Saloon Lighting
2x Traction Cooling Fans
Battery Charger
What runs off the 400/220vAC System? (5)
Battery Charger
2x Air Compressors
2x Traction Cooling Fans
HVACs
220vAC GPO
What are the 4 causes of a flashing door close light?
Saloon door failing to close and lock
Fault within door system
Coupler fault after uncoupling
DER activated