Week #12 - High Rise MD Fires Flashcards
When does ventilation of the fire apartment occur?
After main body of fire is controlled.
Who limits and controls horizontal ventilation of the fire apartment?
Ladder Officer
Who controls all other ventilation?
I.C.
When if ever are the elevator machinery room doors used for ventilation?
Only vented after fire is under control, only if wind wont force smoke back into building.
Elevator responsibilities in High Rise MD fires:
1st Ladder - must recall, even if not used
2nd Ladder - ensure ALL elevators are recalled AND searched
If 1st due OV involved in outside operations, and fire above 7th floor, elevator will be operated by a member from the 2nd ladder and/or members designated by the I.C.
Exclusive Buildings - take service elevator to service stairs
Maintain 2 elevators - one in lobby one 2 floors below fire