Tower Ladders are not designed to operate with outriggers and jacks down on only one side. What is the exception?
If apparatus is not on level ground, lower jacks and outrigger on lower side first, then the jacks and the outrigger on the high side until it is as level as possible.
The guide firefighter stays in position on the other side of the rig until the outrigger is completely down.
Some additional clearance can be obtained by the guide man tilting the hinged outrigger pad.
The boom assembly consists of _ box sections that telescope within each other.
4
What does the hydraulic holding valve do?
In the event of a hydraulic line failure, the hydraulic holding valve will prevent the boom from moving.
The floor area of the basket is approximately how many square feet?
15 square feet
Whenever a tower ladder operation is in progress what must be staffed?
The pedestal must be staffed.
Switch/Controls/Buttons on Pedestal:
Master Power Switch Engine Start Button Platform Control (Activates the Basket Control Station) Deadman Control Pressure Gauge Communication Switch Accessories - lights
2 Ways to escape from the basket:
Fixed telescoping ladder mounted on the top section of the boom
OR
L.S.R.
Boom rotation permits water stream coverage of _ degrees.
360 Degrees
The water system hook up consists of what on a tower ladder?
3” X 3” Gated Siamese on the left side
and
4 1/2” inlet on the right side
What is the most effective way of communicating from the basket to the pedestal?
Intercom. (Checked daily)
If intercom and h.t. fail what should be done to communicate?
Use predetermined hand signals.
Detailed members cannot operate on the pedestal unless?
They are from a tower ladder or are a L.C.C.
What is the “Scrub Area”?
Scrub Area is defined as the area of a building that can be touched by the basket.
How can the scrub area be increased?
By parking the apparatus with the front end angled out about 15 degrees from the building line.
When should positioning the apparatus perpendicular to a building be considered?
When the ground is of doubtful stability. (Vacant lot or other unpaved area that may contain voids)
This is done to reduce the chance of pole vaulting.
Properly positioned Tower Ladder provides a maximum basket floor elevation of _ feet at the maximum _ degree angle.
Floor elevation of 70 feet
Maximum 75 degree angle
Basket when touching a point of 32 feet horizontally from the center of the turntable can reach _ feet high.
32 feet horizontal from turntable can reach 65 feet high.
Tower Ladder scrub area covers what?
Scrub area covers a 60 foot high 50 foot wide.
And will cover a 100 foot frontage on the lower 3 floors of a building.
T.L. has a scrub area of approximately 7750 square feet when the center of the turntable is 32 feet from the building wall and the cab is at a 15 degree angle from the building line.
T.L. has a scrub area of approximately 7750 square feet when the center of the turntable is 32 feet from the building wall and the cab is at a 15 degree angle from the building line.
The basket can reach _ feet below grade.
Basket can reach 10 feet below grade.
Ideal horizontal distance from objective is _ feet.
32 feet. This takes into consideration sidewalks, outriggers and parked cars.