vacants
what is the paramount concern
life hazards
Vacants
what color, how and where is a vacant marked?
lime yellow, 18”x18” square with 2” lines. Marked alongeside the front enterance
vacants
is in-line pumping or backstretch recommended
in line pumping
5 disadvantages of in-line pumping
1-water supply limited
2-may not attain full pumper capacity
3-possibly blocking AL or TL
4-if hydrant is OOS may not be able to move
5- possible damage to rig from falling debris
when stretching a hose into an exposure to operate it into the fire building what size hose should you stretch?
2 1/2” hose
when placing a tower ladder in a vacant lot, who will survey the lot?
the officer and LCC
shoring will be necessary
vacant
R.O will be spray painted on which 3 locations
inside of bulkhead, outside of bulkhead, above the vacant marking on the front
vacants
T/F
bed springs can be used to cover holes
True
vacants
how do you mark a building with floors open?
F.O. underneath the vacant marking square with X inside