Unit 6 Flashcards
What pit depth requires an additional stop switch when the Pit is accessed from the lowest landing hall door, as per the ASME A17.1/CSA B44 code?
1700mm (67in)
When are drains or sump pumps required in elevator pits, as per the ASME A17.1/CSA B44 code?
Elevator is provided with fire fighters emergency operation
What term is used to describe the maximum amount of travel of a buffer?
Stroke
Where should the plumb line be suspended from when plumbing a hydraulic jack?
Top of hoistway
What is the minimum distance from the centre line of pit ladder rungs to any permanent object behind the ladder, as per the ASME A17.1/CSA B44 code?
115mm (4.5inch)
What is required on a pit access door when any mechanical or structural part installed beneath the car platform projects below the top of the access door at the lowest landing?
An electric contact that prevents elevator operation and a vision panel
How is a hydraulic piston attached to a car sling?
Platen plate
What is the recommended procedure to dress a piston should it become nicked or scratched?
Polish with 320 grit or finer sandpaper
Which tool would provide the best method to plump a cylinder?
Spider bob
When can reduce stroke buffers be used on high rise elevators as per the ASME A17.1/CSA B44 code?
Emergency terminal speed-limiting devices are installed