Training Bullitin 8 Electrical Hazards Flashcards

1
Q

What is considered high voltage?

A

Over 600 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How big an area should be cleared for a downed conductor?

A

At least 1 pole span

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

How often are gauntlet gloves tested by DWP?

A

Every 60 days

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How much do manhole covers weigh?

A

300 pounds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many volts are in street lights?

A

Up to 4800 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

According to training bulletin 8 - electrical hazards, what is extremely high voltage, high voltage and low voltage?

A

Excess of 60k

600-59,999

Under 600

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Street lights can be fed from conductors carrying what voltage?

A

120-6150 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When applying water to an electrical fire, what is the rule for psi, cone and distance from object

A

30/33/100

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When using fire line tape to secure an area of life hazards zone, how should you apply strands?

A

Minimum of 3 horizontal lines with fire line or flagging tape at least 1-3 inches in diameter , with the words do not enter or don not cross

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When having occupants remove their own vehicle from possible electrical charge, what is the minimum distance they should move their vehicle from the danger?

A

35 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

DWP can de-energize power lines in a relatively short period of time according to training bulletin 8 a electrical hazards. What is the time frame?

A

Between 5-10 min

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When operating at a brush fire maintain a safe distance of ____feet from transmission towers, maintain at least ______feet from the outer most wires from transmission lines and never direct a hose stream into heavy plumes of smoke with in _____feet of high voltage wires.

A

35 feet
100 feet
100 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

According to training bulletin 8- electrical hazards, man hole cover can weigh _____lbs, and have been blown ____feet into the air and travelled _____feet

A

300 lbs
75 feet
125 feet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the flash point of the cooling oil that is used electrical vaults?

A

300

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Low voltage secondary lines carry how many volts?

A

120-240 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What are AMPS?

A

Current flow

Similar to gpm

AMPS= watts/volts

17
Q

What are volts?

A

Pressure

18
Q

What are watts?

A

The amount of actual power

19
Q

Generation facilities generate how much power?

A

4,000-20,000 volts

20
Q

The insulators on transmission towers are how far apart?

A

3’-20’ depending on voltage

21
Q

Receiving stations reduce power to how many volts?

A

34,500

22
Q

Distribution stations reduce power to how many volts?

A

4,800

23
Q

Overhead transformers reduce power to how many volts?

A

120/240 volts

24
Q

What are the 3 ways to determine high voltage lines?

A

1) high voltage signs
2) size of insulators
3) distance between conductors

25
Q

Heart paralysis can occur at how many AMPS?

A

4

26
Q

Tissue is burned at how many amps?

A

Greater than 5 amps

27
Q

Respiratory arrest has occurred when shocked at as low as how many volts?

A

49

28
Q

Communication cables can have up to how many volts?

A

50

29
Q

What is the explosive range of carbon monoxide?

A

12.4-74%

30
Q

Wet skin may have a resistance of up to how many ohms?

Dry skin?

A

Wet skin- 1000 ohms

Dry skin- 100,000 ohms

31
Q

What is the lowest amps a fuse or circuit breaker will open?

A

15 AMPS

32
Q

For every minute defibrillation is delayed chance of survival decreases what percent?

A

10%

33
Q

600 volts can be up to how many amps?

A

4