Training Bulletin 140- Elevator Operations At Highrise Incidents Flashcards
Firefighters wearing personal protective equipment and carrying necessary equipment require approximately ___ minute(s) per floor to ascend stairs.
1 minute
fire doubles in size every ________ it burns unchecked.
Minute
buildings with split banks of elevators, which may be used if the highest floor served by the elevator shaft terminates a minimum of ___ floors below the reported fire floor.
5
Is the elevator key removable when the switch is in the bypass position.
No
Elevator ascent during investigations or firefighting operations shall only be used when the reported location is above the ___ floor.
6th
Elevators shall not be taken closer than ___ floors below the reported fire floor or ___ floors below the lowest indicated alarm floor location.
2
2
Can firefighters use elevators that travel through a blind shaft?
Yes, but should be avoided whenever possible
The City of Los Angeles enacted a high-rise retrofit ordinances (effective in 1989) that requires all elevators on all levels in all existing high-rise buildings open into elevator lobbies which are separated from the remainder of the building, including corridors and other exits, by walls having a fireresistive rating of not less than ___ hour.
One hour
All lobby openings for elevator doors shall be protected with _____ hour automatic-closing fire assemblies with magnetic hold-open devices for door closure actuated by any initiating device located on the floor
3/4 hour ( 45 minutes )
The fire attack team shall consist of a minimum of ___ members.
4
No more than ___ personnel with equipment shall be permitted in any one elevator at a time
6
f determined that an elevator is going to be used for ascent, precautionary stops shall be made every ___ floors in order to test and confirm that the elevator is properly operating in Phase II as designed.
5
At what stop upon assent should the elevator shaft should once again be checked for the presence of smoke or water. It is not necessary to repeat the control panel checks again.
2nd stop