Tools 36 Digital in-line gauge Flashcards
The red digital readout will ultimately flash a high pressure alert - “high – P” and when pressure exceeds?
200 psi (201)
The blue digital readout will alternately flash high flow alert hi-f water flow exceeds_____
250 gpm (251)
The blue digital readout will alternately flash a low flow alert “Lo-F” One water flow is less than___
80 gpm (79)
If there has been no water flow for____ minutes, the digital display will go into a sleep mode and not display any readings. The resumption of water flow during the sleep mode will reactivate the digital display automatically.
15 mins
If there has been no water flow after ___ minutes, the digital display will power off automatically. If operationsare then resumed, the digital in line gauge will need to be restarted by firmly pressing and holding the ____ on off button for _______ seconds
30 mins; Green; 4-5 seconds
The digital in line gauge is powered by a _________ battery
Special 9 V rechargeable lithium ion battery. No other 9 V battery may be used in this equipment.
Units will be issued____ batteries.
- One battery to be installed in the digital in-line gauge. One battery to be kept in the clear battery pouch of the carrying case. Storing only one spare battery in the keys will prevent damage to batteries due to battery terminal cross contact. Two batteries are to be placed in the charging unit at quarters. Units may put identification numbers or letters on batteries in order to track and evenly rotate them. Company commanders shell establish the schedules that will facilitate this battery rotation
A fully charged battery will supply approximately ___hours of continuous operation. After ____hours of usage the digital readout will _____flash “Lo-batt.” This is an indication that approximately ___minutes of battery life remain. If a slowly flashing low bat is displayed, the battery shall be swapped out when?
5 hours; 3.5 hours; slowly; 99 mins; At the conclusion of the operation
When____ minutes of battery life remains, the digital readout will flash “Lo batt.” If a rapidly flashing “Lo batt” is displayed the battery shall be swapped out with the replacement in the caring case when?. This can be done when water is flowing.
10 minutes; as soon as possible
Condition of the battery installed in the gauge is to be checked ______ using this battery test function.
Each tour; a battery in serviceable condition will display as BATT good
Battery should be rotated and re-charged _____and_____
Weekly; and after use. Remove the batteries from the digital in line gauge and the carry case. Rotate them with batteries from the charging unit two and two out.
The battery charger indicator is a _____color, the inserted battery is charging
Red
A steady what color indicates a fully charged battery. Hey slowly blinking what color indicates a defective battery that must be replaced
Steady green equals fully charged. Slowly blinking red equals defective battery.
The digital in-line gauge should be inspected for damage and operability when?
Each tour
If the digital in line Gage needs to be placed out of service, or replacement batteries are required, do what?
Complete form RT2 and notify the fire tools and equipment unit at 718-391–9405